FT-S8 – Fluorescence dissolved oxygen sensor, RS-485 and 4-20mA output

Fluorescence dissolved oxygen sensor, RS-485 and 4-20mA output

Oxygen Sensors

  • 0-20mg/L
  • 0.2W, 12V power supply
  • -5~+65℃
  • ±2%, ±0.3℃
Manufacturer part number
DISSOLVED-OXYGEN-SENSOR
Manufacturer
Fengtu
Measuring Range
0-20mg/L
Power consumption
0.2W, 12V power supply

FT-S8 fluorescence dissolved oxygen sensor for immersion measurement of dissolved oxygen in water, with RS-485 Modbus/RTU and 4-20mA outputs.

Product overview

Overview. The FT-S8 dissolved oxygen sensor from Fengtu is a fluorescence lifetime dissolved oxygen sensor for measuring dissolved oxygen in water and wastewater. It works on the quenching of excited fluorescence by oxygen molecules at the surface of the fluorescent membrane head: the fluorescence lifetime is measured, converted into concentration and automatically temperature-compensated.

Main characteristics. Measuring range of 0 to 20 mg/L with a resolution of 0.01 mg/L. Accuracy of ±2% and ±0.3 ℃. Two-point calibration. Immersion installation with 3/4 NPT mounting thread. 5 m cable.

Interfaces and connectivity. RS-485 (Modbus/RTU) and 4-20mA outputs. The cable is a 4-core shielded cable: red wire for power, blue wire for ground (GND), green wire for 485B and yellow wire for 485A. Cable colours may vary between production batches; refer to the cable screen print.

Power and environment. DC power supply of 12V to 24V, power consumption of 0.2W at 12V. Protection level IP68. Working environment 0 to 50 ℃, below 0.3 MPa. Storage between -5 and +65 ℃.

Typical uses. Suited to monitoring dissolved oxygen in water and wastewater, and to integration into a data acquisition system using the Modbus/RTU protocol. Sensor data can feed a photovoltaic weather station for environmental monitoring of a distributed PV power plant.

Maintenance. Rinse the outer surface with clean water and clean the fluorescent membrane head gently to avoid scratching the measuring area. Zero calibration can be performed with a sodium sulfite solution, then slope calibration in air-saturated water.

See all specifications

Highlights

  • Accuracy: ±2%, ±0.3℃
  • Cable Length: 5m
  • Calibration method: Two-point calibration
  • Installation: Immersion installation, 3/4NPT mounting thread
  • Measuring Principle: Fluorescence lifetime method
  • Measuring Range: 0-20mg/L

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Oxygen Sensors
Request a quote