DISSOLVED-OXYGEN-SENSOR
Fluorescence dissolved oxygen sensor, RS-485 and 4-20mA output

- Measuring Range
- 0-20mg/L
- Power consumption
- 0.2W, 12V power supply
- Storage Temperature
- -5~+65℃
- Accuracy
- ±2%, ±0.3℃
Fluorescence dissolved oxygen sensor, RS-485 and 4-20mA output
FT-S8 fluorescence dissolved oxygen sensor for immersion measurement of dissolved oxygen in water, with RS-485 Modbus/RTU and 4-20mA outputs.
Overview. The FT-S8 dissolved oxygen sensor from Fengtu is a fluorescence lifetime dissolved oxygen sensor for measuring dissolved oxygen in water and wastewater. It works on the quenching of excited fluorescence by oxygen molecules at the surface of the fluorescent membrane head: the fluorescence lifetime is measured, converted into concentration and automatically temperature-compensated.
Main characteristics. Measuring range of 0 to 20 mg/L with a resolution of 0.01 mg/L. Accuracy of ±2% and ±0.3 ℃. Two-point calibration. Immersion installation with 3/4 NPT mounting thread. 5 m cable.
Interfaces and connectivity. RS-485 (Modbus/RTU) and 4-20mA outputs. The cable is a 4-core shielded cable: red wire for power, blue wire for ground (GND), green wire for 485B and yellow wire for 485A. Cable colours may vary between production batches; refer to the cable screen print.
Power and environment. DC power supply of 12V to 24V, power consumption of 0.2W at 12V. Protection level IP68. Working environment 0 to 50 ℃, below 0.3 MPa. Storage between -5 and +65 ℃.
Typical uses. Suited to monitoring dissolved oxygen in water and wastewater, and to integration into a data acquisition system using the Modbus/RTU protocol. Sensor data can feed a photovoltaic weather station for environmental monitoring of a distributed PV power plant.
Maintenance. Rinse the outer surface with clean water and clean the fluorescent membrane head gently to avoid scratching the measuring area. Zero calibration can be performed with a sodium sulfite solution, then slope calibration in air-saturated water.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DISSOLVED-OXYGEN-SENSOR, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | ±2%, ±0.3℃ |
| Cable Length | 5m |
| Calibration method | Two-point calibration |
| Installation | Immersion installation, 3/4NPT mounting thread |
| Measuring Principle | Fluorescence lifetime method |
| Measuring Range | 0-20mg/L |
| Output Method | RS-485 (Modbus/RTU), 4-20mA |
| Photovoltaic Weather Stations | Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants |
| Power consumption | 0.2W, 12V power supply |
| powered by | DC: 12V-24V |
| Protection Level | IP68 |
| Resolution | 0.01mg/L |
| Storage Temperature | -5~+65℃ |
| Temperature Compensation | Automatic temperature compensation |
| Water PH Sensor | Selection, Installation, and Maintenance |
| Working Environment | 0-50℃, <0.3MPa |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for DISSOLVED-OXYGEN-SENSOR. For a missing document or a specific revision, our experts send it to you.
FT-S8 fluorescence dissolved oxygen sensor for immersion measurement of dissolved oxygen in water, with RS-485 Modbus/RTU and 4-20mA outputs.
| Parameter | Value |
|---|---|
| Accuracy | ±2%, ±0.3℃ |
| Cable Length | 5m |
| Calibration method | Two-point calibration |
| Installation | Immersion installation, 3/4NPT mounting thread |
| Measuring Principle | Fluorescence lifetime method |
| Measuring Range | 0-20mg/L |
| Output Method | RS-485 (Modbus/RTU), 4-20mA |
| Photovoltaic Weather Stations | Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants |
| Power consumption | 0.2W, 12V power supply |
| powered by | DC: 12V-24V |
| Protection Level | IP68 |
| Resolution | 0.01mg/L |
| Storage Temperature | -5~+65℃ |
| Temperature Compensation | Automatic temperature compensation |
| Water PH Sensor | Selection, Installation, and Maintenance |
| Working Environment | 0-50℃, <0.3MPa |
Answers to the questions that the recorded characteristics of DISSOLVED-OXYGEN-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output Method": RS-485 (Modbus/RTU), 4-20mA.
Yes — recorded under "Output Method": RS-485 (Modbus/RTU), 4-20mA.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Fluorescence dissolved oxygen sensor, RS-485 and 4-20mA output

Oxygen Sensors

RS485 Fluorescence Dissolved Oxygen Sensor (Freshwater)

RS485 Fluorescence Dissolved Oxygen Sensor (Seawater)

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DISSOLVED-OXYGEN-SENSOR |
| Manufacturer | Fengtu |
Oxygen Sensors
Fluorescence dissolved oxygen sensor with RS-485 and 4-20mA · Ref. : WQ-DO-4A
Price on request
Oxygen Sensors
Drinking Water Dissolved Oxygen Sensor Probe · Ref. : ADVANCED_DRINKING_WATER_DISSOLVED_OXYGEN_SENSOR_PROBE
Price on request
Oxygen Sensors
Wall-Mounted Oxygen Transmitter with RS485 Output · Ref. : OXYGEN-SENSOR
Price on request
Oxygen Sensors
Industrial dissolved oxygen sensor, 0-20 mg/L range · Ref. : DOG-209FA
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details