SEN0680
Freshwater RS485 fluorescence dissolved oxygen sensor

- Operating Temperature
- 0-40°C
- Measuring Range
- 0-20mg/L, 0-200% Saturation
- Communication interface
- RS485 (Standard ModBus-RTU Protocol)
- Power consumption
- 0.2W
Freshwater RS485 fluorescence dissolved oxygen sensor
Optical dissolved oxygen probe for freshwater, electrolyte-free, with RS485 Modbus-RTU output and IP68 rating, intended for aquaculture and environmental monitoring.
Overview. The DFRobot SEN0680 is a fluorescence dissolved oxygen sensor with an RS485 interface (Modbus-RTU), designed for freshwater environments. It measures dissolved oxygen over a range of 0-20 mg/L (0-200% saturation) with an error of ±3% FS.
Measurement principle. Measurement is based on fluorescence, an optical method that uses no electrolyte and does not consume oxygen. The fluorescent film has a lifespan of 1 year under normal use, and the sensor requires no electrolyte replacement.
Main characteristics. Resolution of 0.01 mg/L, 0.1% and 0.1°C. Measurement error of ±0.5°C at 25°C. Response time ≤60s. Power consumption of 0.2W. Pressure resistance of 0.6MPa.
Connectivity. RS485 interface with standard Modbus-RTU protocol, allowing connection to PLCs, data loggers or industrial monitoring systems. 5m cable.
Power and environment. DC10-30V power supply. IP68 waterproof rating. Operating temperature of 0-40°C. Corrosion-resistant plastic casing.
Typical uses. Dissolved oxygen monitoring in freshwater aquaculture, wastewater treatment and long-term environmental monitoring.
Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for SEN0680, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | ≤60s |
| Cable Length | 5m |
| Casing material | Corrosion-Resistant Plastic |
| Communication interface | RS485 (Standard ModBus-RTU Protocol) |
| Fluorescent Film Lifespan | 1 year under normal use |
| Measurement Error | ±3% FS; ±0.5°C (25°C) |
| Measurement Principle | Fluorescence |
| Measuring Range | 0-20mg/L, 0-200% Saturation |
| Operating Temperature | 0-40°C |
| Power consumption | 0.2W |
| Power supply | DC10-30V |
| Pressure Resistance | 0.6MPa |
| Resolution | 0.01mg/L; 0.1%; 0.1°C |
| Waterproof rating | IP68 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for SEN0680. For a missing document or a specific revision, our experts send it to you.
Optical dissolved oxygen probe for freshwater, electrolyte-free, with RS485 Modbus-RTU output and IP68 rating, intended for aquaculture and environmental monitoring.
| Parameter | Value |
|---|---|
| Response time | ≤60s |
| Cable Length | 5m |
| Casing material | Corrosion-Resistant Plastic |
| Communication interface | RS485 (Standard ModBus-RTU Protocol) |
| Fluorescent Film Lifespan | 1 year under normal use |
| Measurement Error | ±3% FS; ±0.5°C (25°C) |
| Measurement Principle | Fluorescence |
| Measuring Range | 0-20mg/L, 0-200% Saturation |
| Operating Temperature | 0-40°C |
| Power consumption | 0.2W |
| Power supply | DC10-30V |
| Pressure Resistance | 0.6MPa |
| Resolution | 0.01mg/L; 0.1%; 0.1°C |
| Waterproof rating | IP68 |
Points to check before using SEN0680 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power consumption | 0.2W |
| Power supply | DC10-30V |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of SEN0680 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication interface": RS485 (Standard ModBus-RTU Protocol).
Yes — recorded under "Communication interface": RS485 (Standard ModBus-RTU Protocol).
0-40°C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Freshwater RS485 fluorescence dissolved oxygen sensor

RS485 Fluorescence Dissolved Oxygen Sensor (Seawater)

Dissolved Oxygen Sensor

Dissolved oxygen sensor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | SEN0680 |
| Manufacturer | DFRobot |
Oxygen Sensors
Fluorescence dissolved oxygen sensor with RS-485 and 4-20mA · Ref. : WQ-DO-4A
Price on request
Oxygen Sensors
Drinking Water Dissolved Oxygen Sensor Probe · Ref. : ADVANCED_DRINKING_WATER_DISSOLVED_OXYGEN_SENSOR_PROBE
Price on request
Oxygen Sensors
Wall-Mounted Oxygen Transmitter with RS485 Output · Ref. : OXYGEN-SENSOR
Price on request
Oxygen Sensors
Industrial dissolved oxygen sensor, 0-20 mg/L range · Ref. : DOG-209FA
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details