DISSOLVED-OXYGEN-METER
Fluorescence Dissolved Oxygen Sensor RS485

- Measure range
- 0~20mg/L (0~200% saturation)
- Power consumption
- 0.2W
- Response time
- ≤60s
- Electrode wire length
- Default 5m
Fluorescence Dissolved Oxygen Sensor RS485
Renke fluorescence dissolved oxygen sensor for measuring the dissolved oxygen in water to reflect water quality, with RS485 output.
Overview. The Renke RS-LDO*-N01-2-20-T is a dissolved oxygen sensor for measuring the concentration of dissolved oxygen in water to reflect its quality. It works on the fluorescence principle, so it does not consume oxygen and requires no electrolyte.
Measurement characteristics. The measurement range is 0~20 mg/L (0~200% saturation), with a resolution of 0.01 mg/L, 0.1% and 0.1℃. The measurement error is ±0.3 mg/L and ±0.5℃ at 25℃. The response time is ≤60s. The fluorescent film lifespan is 1 year under normal use. A built-in temperature transmitter provides automatic temperature compensation.
Interfaces and connectivity. The signal output is RS485, and the sensor supports adjustable Modbus communication address and baud rate settings. The default electrode wire length is 5m.
Power and environment. The sensor is powered by DC 10~30V with a power consumption of 0.2W. It has an IP68 protection class, a pressure resistance of 0.6MPa and an operating temperature range of 0~40℃. The standard type has a shell in corrosion-resistant plastic and stainless steel, and the economy type in corrosion-resistant plastic.
Typical uses. This sensor suits water quality monitoring in water treatment, aquaculture, rivers, lakes and seawater quality monitoring, as well as surface water, groundwater and wastewater.
Integration. The sensor connects to a supervision system through its RS485 link using the Modbus protocol. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for DISSOLVED-OXYGEN-METER, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | ≤60s |
| Electrode wire length | Default 5m |
| Fluorescent Film Lifespan | 1 year under normal use |
| Measure error | ±0.3 mg/L; ±0.5°C (25°C) |
| Measure range | 0~20mg/L (0~200% saturation) |
| Model | RS-LDO*-N01-2-20-T |
| Operating Conditions | 0~40℃ |
| Power consumption | 0.2W |
| Power supply | DC 10~30V |
| Pressure Resistance | 0.6MPa |
| Protect class | IP68 |
| Resolution | 0.01mg/L; 0.1%; 0.1℃ |
| Shell material | Standard type: Corrosion-resistant plastic, stainless steel; Economy type: Corrosion-resistant plastic |
| Signal Output | RS485 |
| Working Principle | Fluorescence Method |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for DISSOLVED-OXYGEN-METER. For a missing document or a specific revision, our experts send it to you.
Renke fluorescence dissolved oxygen sensor for measuring the dissolved oxygen in water to reflect water quality, with RS485 output.
| Parameter | Value |
|---|---|
| Response time | ≤60s |
| Electrode wire length | Default 5m |
| Fluorescent Film Lifespan | 1 year under normal use |
| Measure error | ±0.3 mg/L; ±0.5°C (25°C) |
| Measure range | 0~20mg/L (0~200% saturation) |
| Model | RS-LDO*-N01-2-20-T |
| Operating Conditions | 0~40℃ |
| Power consumption | 0.2W |
| Power supply | DC 10~30V |
| Pressure Resistance | 0.6MPa |
| Protect class | IP68 |
| Resolution | 0.01mg/L; 0.1%; 0.1℃ |
| Shell material | Standard type: Corrosion-resistant plastic, stainless steel; Economy type: Corrosion-resistant plastic |
| Signal Output | RS485 |
| Working Principle | Fluorescence Method |
Answers to the questions that the recorded characteristics of DISSOLVED-OXYGEN-METER can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal Output": RS485.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Fluorescence Dissolved Oxygen Sensor RS485

RS485 Fluorescence Dissolved Oxygen Sensor (Freshwater)

RS485 Fluorescence Dissolved Oxygen Sensor (Seawater)

SUP-DO7013 Electrochemical dissolved oxygen sensor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | DISSOLVED-OXYGEN-METER |
| Manufacturer | Renke |
Oxygen Sensors
Fluorescence dissolved oxygen sensor with RS-485 and 4-20mA · Ref. : WQ-DO-4A
Price on request
Oxygen Sensors
Drinking Water Dissolved Oxygen Sensor Probe
Price on request
Oxygen Sensors
Wall-Mounted Oxygen Transmitter with RS485 Output
Price on request
Oxygen Sensors
Industrial dissolved oxygen sensor, 0-20 mg/L range · Ref. : DOG-209FA
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details