UEC1-50C
3-pole AC-3 power contactor 50 A, 50/60 Hz coil

- Hold-in Power Consumption in VA
- 20 VA 50/60 Hz (at 25 °C)
- Minimum Switching Current
- 0.1A for signalling circuit
- Mounting Support
- Screw; 35mm or 75mm DIN Rail
- Number of Units in Package 1
- 1 pcs
3-pole AC-3 power contactor 50 A, 50/60 Hz coil
The Hongfa UEC1-50C three-pole contactor switches power loads up to 690 V AC. It has 3 NO main contacts and a rated current of 50 A in AC-3 category at 400 V.
Hongfa UEC1-50C contactor. the UEC1-50C three-pole contactor from Hongfa's UEC1 series is a power contactor with an AC coil, designed to switch power circuits up to 690 V AC, 50/60 Hz.
Main characteristics. Three NO power poles, conventional free-air thermal current of 80 A at 60 °C for the power circuit and 50 A rated operational current in AC-3 category at 400 V, with an average contact impedance of 1.5 mΩ. The 10 A signalling circuit provides 1 NO and 1 NC, other combinations being available on request. The 50/60 Hz AC coil is supplied without a built-in suppressor module.
Power ratings and durability. Motor power of 15 kW at 220/230 V, 22 kW at 380/400 V and 33 kW at 660/690 V in AC-3. Electrical durability of 0.9 million cycles at 50 A AC-3 and mechanical durability of 5 million cycles, with a maximum operating rate of 400 cycles/h electrical and 3600 cycles/h mechanical.
Supply and environment. Standard control voltages from 24 V to 415 V AC. Ambient operating temperature range of -40 to 60 °C, IP20 degree of protection on the front face, operating altitude up to 3000 m without derating, overvoltage category III and fire resistance of current-carrying parts at 850 °C per IEC 60695-2-11.
Connection and mounting. Screw-type terminals for the power circuit (torque 5 N·m) and for the control circuit (torque 1.2 N·m). Mounting by screw or on 35 mm or 75 mm DIN rail. Dimensions: 63 mm wide, 112.5 mm high and 132 mm deep, weight 1.0 kg.
Typical use. Control of three-phase and single-phase motors and power loads in electrical cabinets, in accordance with IEC/EN 60947-4-1 and IEC/EN 60947-5-1 standards, with CE, UKCA, VDE, UL (cULus) and CCC certifications.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for UEC1-50C, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 80 A gG at ≤ 690 V coordination type 2 for power circuit |
| Auxiliary Contact Composition | 1NO1NC,2NO2NC,other combinations can be customized |
| Average Impedance | 1.5 mΩ - Ith 50 Hz for power circuit |
| China RoHS Regulation | Conforming |
| Coil Technology | Without built-in suppressor module |
| Control Circuit Voltage Limits | 0.8...1.1 Us (-40…60 °C): operational AC 50 Hz; 0.85...1.1 Us (-40…60 °C): operational AC 60 Hz; 1...1.1 Us (60…70 °C): operational AC 50/60 Hz; 0.2...0.75 Us (-40…70 °C): drop-out AC 50/60 Hz |
| Control Dircuit Type | AC at 50/60 Hz standard |
| Conventional Free Air Thermal Current [Ith] | 80 A (at ≤60 °C) for power circuit; 10 A (at ≤60 °C) for signalling circuit |
| Depth | 132 mm |
| Device Short Name | UEC1-50C |
| Electrical Durability | 0.9 M cycles 50 A AC-3 at Ue ≤ 400 V |
| EU RoHS Directive | Conforming |
| Fire Resistance | Current-carrying parts:850 °C conforming to IEC 60695-2-11 |
| Height | 112.5 mm |
| Hold-in Power Consumption in VA | 20 VA 50/60 Hz (at 25 °C) |
| Inrush Power in VA | 105 VA 50/60 Hz (at 25 °C) |
| Insulation Resistance | > 10 MΩ for signalling circuit |
| IP Degree of Protection | IP20 front face conforming to IEC 60529 |
| Maximum Operating Rate | Electrical: 400 cycs/h; Mechanical: 3600 cycs/h |
| Mechanical Durability | 5 M cycles |
| Mercury Free | Yes |
| Minimum Switching Current | 0.1A for signalling circuit |
| Minimum Switching Voltage | 24 V for signalling circuit |
| Motor Power hp | 3 hp at 110…120 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 200…208 V AC 50/60 Hz for 1 phase motors; 10 hp at 220…240 V AC 50/60 Hz for 1 phase motors; 15 hp at 200…208 V AC 50/60 Hz for 3 phases motors; 15 hp at 220…240 V AC 50/60 Hz for 3 phases motors; 40 hp at 440…480 V AC 50/60 Hz for 3 phases motors; 50 hp at 550…600 V AC 50/60 Hz for 3 phases motors |
| Motor Power kW | 15 kW at 220/230 V AC 50/60 Hz (AC-3); 22 kW at 380/400 V AC 50/60 Hz (AC-3); 33 kW at 660/690 V AC 50/60 Hz (AC-3) |
| Mounting Support | Screw; 35mm or 75mm DIN Rail |
| Net weight | 1.0 kg |
| Number of Units in Package 1 | 1 pcs |
| Number of Units in Package 2 | 12 pcs |
| Operating Altitude | 0...3000 m without derating |
| Operating Time | Power circuit: 12...26 ms closing, 4...19 ms opening; Signalling circuit (NO): 15...26 ms closing, 4...19 ms opening; Signalling circuit (NC): 4...19 ms opening, 12...32 ms closing |
| Overvoltage category | III |
| Package 1 Height | 14.6 cm |
| Package 1 Length | 12.2 cm |
| Package 1 Weight | 1.05 kg |
| Package 1 Width | 7.2 cm |
| Package 2 Height | 18.8 cm |
| Package 2 Length | 41.5 cm |
| Package 2 Weight | 13.80 kg |
| Package 2 Width | 32.5 cm |
| Permissible Ambient Air; Temperature Around the Device | -40…60 °C for normal operating; 60…70 °C with derating (for operation in the range of Us...1.1Us); Storage: -60…80 °C |
| Pole Contact Composition | 3 NO |
| Poles Description | 3P |
| Product Certifications | CCC,CE,UKCA,VDE,UL(cULus LISTED) |
| Product or Component Type | Contactor |
| Product Series | UEC1 |
| Rated operational current (Ie) | 50 A (at ≤60 °C) at ≤ 400 V AC AC-3 for power circuit; 80 A (at ≤60 °C) at ≤ 690 V AC AC-1 for power circuit |
| Rated Operational Voltage (Ue) | Power circuit: ≤ 690 V AC 50/60Hz |
| Rated Short-Time Withstand Current [Icw] | 400 A ≤40 °C - 10 s for power circuit; 810 A ≤40 °C - 1 s for power circuit; 84 A ≤40 °C - 10 min for power circuit; 208 A ≤40 °C - 1 min for power circuit |
| REACh Regulation | Conforming |
| RoHS Exemption Information | Yes |
| Standards | GB/T 14048.4,GB/T 14048.5, IEC/EN 60947-4-1,IEC/EN 60947-5-1,; BS EN 60947-4-1,BS EN 60947-5-1,UL 60947-4-1,UL 60947-5-1 |
| Tightening torque | Power circuit: 45 lb.in(5 N·m)- on bolt clamp terminals - with internal hexagon socket wrench 4 mm; Control circuit: 11 lb.in(1.2 N·m)- on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 11 lb.in(1.2 N·m)- on screw clamp terminals - with screwdriver Philips No 2 |
| [Ui] Rated Insulation Voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V UL Certified; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V UL Certified |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Unit Type of Package 1 | 1 box |
| Unit Type of Package 2 | 1 carton |
| [Us] Control Circuit Voltage; (AC 50/60Hz) | Voltage (V): 24 36 42 48 110 115 127 220 230 240 380 400 415 |
| Utilisation Category | AC-3; AC-4; AC-1 |
| Width | 63 mm |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for UEC1-50C. For a missing document or a specific revision, our experts send it to you.
The Hongfa UEC1-50C three-pole contactor switches power loads up to 690 V AC. It has 3 NO main contacts and a rated current of 50 A in AC-3 category at 400 V.
| Parameter | Value |
|---|---|
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 80 A gG at ≤ 690 V coordination type 2 for power circuit |
| Auxiliary Contact Composition | 1NO1NC,2NO2NC,other combinations can be customized |
| Average Impedance | 1.5 mΩ - Ith 50 Hz for power circuit |
| China RoHS Regulation | Conforming |
| Coil Technology | Without built-in suppressor module |
| Control Circuit Voltage Limits | 0.8...1.1 Us (-40…60 °C): operational AC 50 Hz; 0.85...1.1 Us (-40…60 °C): operational AC 60 Hz; 1...1.1 Us (60…70 °C): operational AC 50/60 Hz; 0.2...0.75 Us (-40…70 °C): drop-out AC 50/60 Hz |
| Control Dircuit Type | AC at 50/60 Hz standard |
| Conventional Free Air Thermal Current [Ith] | 80 A (at ≤60 °C) for power circuit; 10 A (at ≤60 °C) for signalling circuit |
| Depth | 132 mm |
| Device Short Name | UEC1-50C |
| Electrical Durability | 0.9 M cycles 50 A AC-3 at Ue ≤ 400 V |
| EU RoHS Directive | Conforming |
| Fire Resistance | Current-carrying parts:850 °C conforming to IEC 60695-2-11 |
| Height | 112.5 mm |
| Hold-in Power Consumption in VA | 20 VA 50/60 Hz (at 25 °C) |
| Inrush Power in VA | 105 VA 50/60 Hz (at 25 °C) |
| Insulation Resistance | > 10 MΩ for signalling circuit |
| IP Degree of Protection | IP20 front face conforming to IEC 60529 |
| Maximum Operating Rate | Electrical: 400 cycs/h; Mechanical: 3600 cycs/h |
| Mechanical Durability | 5 M cycles |
| Mercury Free | Yes |
| Minimum Switching Current | 0.1A for signalling circuit |
| Minimum Switching Voltage | 24 V for signalling circuit |
| Motor Power hp | 3 hp at 110…120 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 200…208 V AC 50/60 Hz for 1 phase motors; 10 hp at 220…240 V AC 50/60 Hz for 1 phase motors; 15 hp at 200…208 V AC 50/60 Hz for 3 phases motors; 15 hp at 220…240 V AC 50/60 Hz for 3 phases motors; 40 hp at 440…480 V AC 50/60 Hz for 3 phases motors; 50 hp at 550…600 V AC 50/60 Hz for 3 phases motors |
| Motor Power kW | 15 kW at 220/230 V AC 50/60 Hz (AC-3); 22 kW at 380/400 V AC 50/60 Hz (AC-3); 33 kW at 660/690 V AC 50/60 Hz (AC-3) |
| Mounting Support | Screw; 35mm or 75mm DIN Rail |
| Net weight | 1.0 kg |
| Number of Units in Package 1 | 1 pcs |
| Number of Units in Package 2 | 12 pcs |
| Operating Altitude | 0...3000 m without derating |
| Operating Time | Power circuit: 12...26 ms closing, 4...19 ms opening; Signalling circuit (NO): 15...26 ms closing, 4...19 ms opening; Signalling circuit (NC): 4...19 ms opening, 12...32 ms closing |
| Overvoltage category | III |
| Package 1 Height | 14.6 cm |
| Package 1 Length | 12.2 cm |
| Package 1 Weight | 1.05 kg |
| Package 1 Width | 7.2 cm |
| Package 2 Height | 18.8 cm |
| Package 2 Length | 41.5 cm |
| Package 2 Weight | 13.80 kg |
| Package 2 Width | 32.5 cm |
| Permissible Ambient Air; Temperature Around the Device | -40…60 °C for normal operating; 60…70 °C with derating (for operation in the range of Us...1.1Us); Storage: -60…80 °C |
| Pole Contact Composition | 3 NO |
| Poles Description | 3P |
| Product Certifications | CCC,CE,UKCA,VDE,UL(cULus LISTED) |
| Product or Component Type | Contactor |
| Product Series | UEC1 |
| Rated operational current (Ie) | 50 A (at ≤60 °C) at ≤ 400 V AC AC-3 for power circuit; 80 A (at ≤60 °C) at ≤ 690 V AC AC-1 for power circuit |
| Rated Operational Voltage (Ue) | Power circuit: ≤ 690 V AC 50/60Hz |
| Rated Short-Time Withstand Current [Icw] | 400 A ≤40 °C - 10 s for power circuit; 810 A ≤40 °C - 1 s for power circuit; 84 A ≤40 °C - 10 min for power circuit; 208 A ≤40 °C - 1 min for power circuit |
| REACh Regulation | Conforming |
| RoHS Exemption Information | Yes |
| Standards | GB/T 14048.4,GB/T 14048.5, IEC/EN 60947-4-1,IEC/EN 60947-5-1,; BS EN 60947-4-1,BS EN 60947-5-1,UL 60947-4-1,UL 60947-5-1 |
| Tightening torque | Power circuit: 45 lb.in(5 N·m)- on bolt clamp terminals - with internal hexagon socket wrench 4 mm; Control circuit: 11 lb.in(1.2 N·m)- on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 11 lb.in(1.2 N·m)- on screw clamp terminals - with screwdriver Philips No 2 |
| [Ui] Rated Insulation Voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V UL Certified; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V UL Certified |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Unit Type of Package 1 | 1 box |
| Unit Type of Package 2 | 1 carton |
| [Us] Control Circuit Voltage; (AC 50/60Hz) | Voltage (V): 24 36 42 48 110 115 127 220 230 240 380 400 415 |
| Utilisation Category | AC-3; AC-4; AC-1 |
| Width | 63 mm |
Answers to the questions that the recorded characteristics of UEC1-50C can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Auxiliary Contact Composition": 1NO1NC,2NO2NC,other combinations can be customized.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
3-pole AC-3 power contactor 50 A, 50/60 Hz coil




Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | UEC1-50C |
| Manufacturer | Hongfa |
Power Contactors
1 Pole + Shunt 20A-40A Definite Purpose Contactor · Ref. : SA-1.5P
Price on request
Power Contactors
Three-pole power contactor 38 A AC-3 AC coil 50/60 Hz
Price on request
Power Contactors
Technical article: relay versus contactor differences
Price on request
Power Contactors
EPS box with integrated contactors for 1-phase/3-phase inverters · Ref. : X1/X3-EPS
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details