The Netvox Z800R is a ZigBee HA range extender built into a manually switched electrical outlet, used to extend the coverage of a ZigBee HA network.
Consumption@standby mode Frequency:
Frequency2.4-2.4835 GHz
Device typeRange Extender (HA profile)
Product overview
Overview. The Netvox Z800R is a range extender (HA profile) from manufacturer Netvox, built into an electrical outlet. It extends the coverage of a ZigBee HA network and works with any ZigBee HA network.
Main characteristics. The Z800R has the look of the Z800 outlet but without power consumption monitoring and without wireless on/off control. It has a manual switch that toggles the AC output to the connected appliances. The protocol is based on ZigBee.
Connectivity. The extender operates in the 2.4–2.4835 GHz band and uses the ZigBee HA profile to join an existing network.
Power. The input is 100–240 VAC, 50/60 Hz. Versions for various country power sockets are available.
Typical use. Extending the range of a ZigBee HA network by installing a range extender outlet on the mains supply.
The Netvox Z800R is a ZigBee HA range extender built into a manually switched electrical outlet, used to extend the coverage of a ZigBee HA network.
Consumption@standby mode Frequency:
Frequency2.4-2.4835 GHz
Device typeRange Extender (HA profile)
2. Datasheet extract (recorded values)
Parameter
Value
Consumption
@standby mode Frequency:
Device type
Range Extender (HA profile)
Frequency
2.4-2.4835 GHz
Applications and use cases
Architectures in which Z800R can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for Z800R and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details