Three-phase three-wire energy meter of class 0.1S for active and reactive energy measurement, with DLMS, Modbus and DNP3 communication for remote reading and monitoring.
Temperature range-Storage- 10 - 85℃
Voltage Range80%Un - 120%Un
Communication interface1*Optical Port
I/O interface5*Signal Inputs
Current circuit apparent power at In<1.3 VA
Maximum current Imax6A/20A
Product overview
Overview. The Reallin Three Phase Three Wire Class 0.1S Meter measures energy on three-phase three-wire networks. It offers class 0.1S accuracy for active energy and class 0.5S for reactive energy.
Main characteristics. Rated voltage 3P3W of 3×110 V, reference current In of 1 A or 5 A, maximum current Imax of 6 A or 20 A, minimum current Imin of 0.01 A or 0.05 A and starting current Ist of 0.1% In. Rated frequency 50 Hz, voltage range 80% Un to 120% Un. Pulse constant of 50000 imp/kWh and 50000 imp/kvarh, with LED pulse indicator. Color LCD display with configurable decimal places, backlight supported, real-time clock compliant with IEC 62054-21. Weight about 1.9 kg, dimensions 272.0 × 174.5 × 80.5 mm.
Interfaces and connectivity. One optical port and five signal inputs. Communication protocols DLMS, Modbus and DNP3, the latter two intended for SCADA systems.
Power and environment. Auxiliary supply of 50 to 280 V AC or DC, with auxiliary supply taking first priority. Voltage circuit consumption below 1 W and 1 VA, powered by the auxiliary supply. Replaceable battery and internal super capacitor as backup power. Protection degree IP 54, insulation class II, operation from -10 to 70 °C, storage from -10 to 85 °C.
Typical uses. Remote reading and monitoring of energy consumption on three-phase three-wire networks, for example through a SCADA system using the Modbus or DNP3 protocol.
Three-phase three-wire energy meter of class 0.1S for active and reactive energy measurement, with DLMS, Modbus and DNP3 communication for remote reading and monitoring.
Temperature range-Storage- 10 - 85℃
Voltage Range80%Un - 120%Un
Communication interface1*Optical Port
I/O interface5*Signal Inputs
Current circuit apparent power at In<1.3 VA
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
Class 0.1S for active; Class 0.5S for reactive
Auxiliary Supply Facility
Support auxiliary supply facility with 50 - 280V (AC or DC); AUX first priority
Backup power supply
Replaceable battery and internal super capacitor
Communication interface
1*Optical Port
Communication Protocol
DLMS/Modbus/DNP3 (Modbus & DNP3 is for SCADA)
Current circuit apparent power at In
<1.3 VA
Dimension(L×W ×D)
272.0×174.5×80.5mm
Environment
Operation- 10 - 70℃
I/O interface
5*Signal Inputs
Insulation Class
II
LCD display
Color display with configurable decimal places, backlight supported
Maximum current Imax
6A/20A
Minimum Current (Imin)
0.01A/0.05A
Protection degree
IP 54
Pulsating Indicator
LED
Pulsating(meter constant)
50000imp/kWh; 50000imp/kvarh
Rated Frequency Fn
50Hz
Rated Voltage Un
3P4W - 3×57.7/100 - 240/415V; 3P3W - 3×110V
Reference Current (In)
1A/5A
RTC
Provides RTC with clock accuracy according to IEC62054 - 21
Architectures in which 274734229 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar production, storage and charging points on one site are often managed separately. Inverters, batteries, MPPT controllers, meters and chargers form a local energy system that shares production between users
To check
Regulatory framework for collective self-consumption in the country
Energy management system steering storage and charging
Metering accuracy for sharing between participants
Associated system blocks
ProductionStorageMeteringCharging
Need a complete solution?
Send a request for 274734229 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details