Reallin 3-phase smart energy meter for measuring and recording energy consumption on a 3 x 230/400 V system, with RS485 communication output.
Temperature rangeoperation:-40-70℃
Voltage Range70%un~140%un
Communication interfaceRS485 port,up to38400 b ps
Current circuit apparent power at Ib<1VA
Maximum current Imax80A
Minimum Current (Imin)0.25A
Product overview
Reallin 3-phase energy meter. The Reallin 3-phase energy meter, reference 282180386, is a smart meter designed to measure and record energy consumption in a three-phase AC system. It measures the quantities of the three phases simultaneously.
Accuracy and electrical characteristics. Accuracy class B/1.0 for active energy and class 2.0 for reactive energy. Reference current Ib of 5 A, maximum current Imax of 80 A, minimum current Imin of 0.25 A and starting current Ist of 0.4% Ib. Rated voltage Un of 3x230/400 V, voltage range 70% Un to 140% Un, rated frequency Fn of 50 Hz. Pulse constant of 1000 imp/kWh and 1000 imp/kvarh, with LED pulse indicator.
Display and communication. Dot matrix LCD with backlight. RS485 communication interface up to 38400 bps, allowing connection to a supervision system or PLC over the serial bus.
Power, environment and protection. Current circuit apparent power at Ib below 1 VA, voltage circuit power at or below 1.5 W / 8 VA. Operating temperature range -40 to 70 °C. Protection degree IP51 in protective enclosure, insulation class II. Dimensions 90 x 52.5 x 62 mm, weight about 0.3 kg.
Standards and typical uses. Compliant with EN 50470-3:2022, IEC 62053-21/23:2020, IEC 62052-31:2015, UL 61010-1 and UL 61010-2-030. Typical use: three-phase energy metering in installations where consumption must be read remotely via RS485. Available on quotation from Atlas Electronics.
Reallin 3-phase smart energy meter for measuring and recording energy consumption on a 3 x 230/400 V system, with RS485 communication output.
Temperature rangeoperation:-40-70℃
Voltage Range70%un~140%un
Communication interfaceRS485 port,up to38400 b ps
Current circuit apparent power at Ib<1VA
Maximum current Imax80A
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
class B/1.0 for active; class 2.0 for reactive
Communication interface
RS485 port,up to38400 b ps
Current circuit apparent power at Ib
<1VA
Dimension(LXW XD)
90x52.5x62mm
Insulation Class
II
LCD display
Dot Matrix type,backlight supported
Maximum current Imax
80A
Minimum Current (Imin)
0.25A
port ect ion Degree
IP51 in protective enclosure
Pulsating Indicator
LED
Pulsating(meter constant)
1000 imp/kwh; 1000 imp/kvarh
Rated Frequency Fn
50HZ
Rated Voltage Un
3x230/400v
Reference current Ib
5A
Standards
EN 50470-3:2022,IEC 62053-21/23:2020,IEC 62052-31:2015,UL61010-1,UL61010-2-030
Starting Current (Ist)
0.4%Ib
Temperature range
operation:-40-70℃
voltage circuit active lap parent power atun
≤ 1.5W/8VA
Voltage Range
70%un~140%un
Weight Of Meter
About0.3kg
Applications and use cases
Architectures in which 282180386 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for 282180386 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
282180386
3-Phase Smart Energy Meter with RS485 Communication
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details