Single-phase 230 V energy meter with a 6+4 digit LCD display, measuring active and reactive energy on low-voltage networks, with RS485 communication output.
Temperature rangeOperation:-30~70℃; Storage:-40~85℃
Voltage Range80%Un~120%Un
Current circuit apparent power at Ib<1VA
Maximum current Imax65A
Minimum Current (Imin)0.25A
Reference current Ib5A
Product overview
Reallin. single-phase 230 V energy meter with electricity display. This meter measures active and reactive energy on single-phase low-voltage networks and shows the values on a 6+4 digit LCD display.
Main characteristics. Rated voltage Un of 230 V/240 V, voltage range of 80% to 120% Un, rated frequency of 50/60 Hz, reference current Ib of 5 A and maximum current Imax of 65 A. Starting current of 0.4% Ib and minimum current of 0.25 A. Dimensions of 90×35×62 mm for a weight of about 0.13 kg.
Accuracy and pulses. Class B/1.0 for active energy and class 2.0 for reactive energy. Pulse constant of 1000 imp/kWh and 1000 imp/kvarh, indicated by an LED pulsating indicator.
Interfaces and connectivity. RS485 communication interface with screw terminals, up to 115200 bps, allowing data to be read by a supervision system or a PLC.
Power and environment. Voltage circuit consumption of 1.5 W / 8 VA at Un and current circuit apparent power below 1 VA at Ib. Operating temperature from -30 to 70 ℃, storage from -40 to 85 ℃. Protection degree IP51 in protective enclosure, insulation class II.
Standards. EN 50470-3:2022, IEC 62053-21/23:2020, IEC 62052-11:2020, IEC 62052-31:2015, UL61010-1 and UL61010-2-030.
Typical uses. Energy metering and sub-metering on low-voltage installations, with data transmitted to an energy management system over the RS485 link.
Integration. Available on quotation from Atlas Electronics.
Single-phase 230 V energy meter with a 6+4 digit LCD display, measuring active and reactive energy on low-voltage networks, with RS485 communication output.
Temperature rangeOperation:-30~70℃; Storage:-40~85℃
Voltage Range80%Un~120%Un
Current circuit apparent power at Ib<1VA
Maximum current Imax65A
Minimum Current (Imin)0.25A
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
Class B/1.0 for active; Class 2.0 for reactive
Communication interface
RS485 with screw type,maximum upto 115200bps
Current circuit apparent power at Ib
<1VA
Dimension(LxWxD)
90×35×62mm
Insulation Class
II
LCD display
6+4 digits
Maximum current Imax
65A
Minimum Current (Imin)
0.25A
Protection degree
IP51 in protectve enclosure
Pulsating Indicator
LED
Pulsating(meter constant)
1000imp/kWh; 1000imp/kvarh
Rated Frequency Fn
50/60Hz
Rated Voltage Un
230V/240V
Reference current Ib
5A
Standards
EN 50470-3:2022,IEC 62053-21/23:2020,IEC 62052-11:2020,; IEC 62052-31:2015,UL61010-1,UL61010-2-030
Starting Current (Ist)
0.4%Ib
Temperature range
Operation:-30~70℃; Storage:-40~85℃
Voltage circuit active/apparent power at Un
<1.5W/8VA
Voltage Range
80%Un~120%Un
Weight Of Meter
About 0.13kg
Applications and use cases
Architectures in which 283690616 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for 283690616 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
283690616
Single-phase 230 V energy meter with display, RS485
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.