MH-440D
Methane CH4 NDIR infrared gas sensor

- Detection range
- 0~10% Vol optional
- Measurement Range
- 0~5.00% Vol; 0~10.00% Vol; 100%LEL
- Interface Level
- 3.0V
- Average Current
- <85mA
Methane CH4 NDIR infrared gas sensor
Miniature non-dispersive infrared (NDIR) methane sensor with UART and analog voltage output, designed to replace a catalytic gas sensor directly.
Winsen MH-440D NDIR CH4 sensor. The Winsen MH-440D is a miniature infrared gas sensor that measures methane (CH4) concentration in air using the non-dispersive infrared (NDIR) principle. It is independent of oxygen and does not rely on a chemical reaction for measurement.
Main characteristics. Measurement range of 0 to 5.00% Vol, 0 to 10.00% Vol or 100% LEL depending on the version, with a resolution and accuracy of 0.01% Vol or 1% LEL. The T90 response time is below 30 s, the warm-up time is 3 min and the lifetime exceeds 5 years. The sensor includes temperature compensation and provides an excellent linear output.
Interfaces and connectivity. UART output at 3.0 V interface level and analog voltage output. The sensor is anti-poisoning and resistant to vapour interference.
Power and environment. Working voltage 3.6 to 5.0 VDC, to be supplied through a safety barrier. Average current below 85 mA. Working temperature -20 °C to 60 °C, working humidity 0 to 95 % RH without condensation. Protection rating IP54. Dimensions Φ20 × 22.6 mm, weight 35 g. Intrinsic safety parameters: Ui = 7.5 VDC, Ii = 265 mA, Pi = 0.5 W, Ci = 10 µF, Li = 0 mH.
Typical uses. Indoor air monitoring, industrial process control and safety protection, HVAC and refrigeration, agriculture and animal husbandry, in environments with flammable or explosive gas hazards.
Integration. The sensor can be connected to a PLC or supervision system through its UART output. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MH-440D, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | T90 < 30 s |
| Average Current | <85mA |
| Characteristics | 1. High sensitivity, high resolution, fast response;2. Output method: UART, analog voltage signal;3. Temperature compensation, excellent linear output;4. Excellent stability, Long lifespan;5. Anti-poisons, anti-vapor interference;6. Can replace catalytic |
| Defense Grade | IP54 |
| Detection Gas | Methane (CH4) |
| Detection Principle | non-dispersive infrared (NDIR) principle |
| Detection range | 0~10% Vol optional |
| Interface Level | 3.0V |
| Life Time | >5 years |
| Measurement Range | 0~5.00% Vol; 0~10.00% Vol; 100%LEL |
| Model | MH-440D |
| Output Method | UART, analog voltage signal |
| Output signal | UART(3.0V) |
| Power, communication terminal Intrinsic safety | Ui=7.5VDC,Ii=265mA, Pi=0.5W,Ci=10μ F,Li=0mH |
| Resolution and accuracy | 0.01% Vol, 1%LEL |
| Size | Φ20×22.6mm |
| Sizes | Φ 20×22.6mm |
| Target | CH4 |
| Warm-Up Time | 3 min |
| Weight | 35g |
| Working Conditions | 3.6~5.0V DC(Need to be powered by safety barrier) |
| Working humidity | 0~95%RH (no condensation) |
| Working temperature | -20°C ~ 60°C |
| Working voltage | 3.6~5.0VDC (Need to be powered by safety barrier) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for MH-440D. For a missing document or a specific revision, our experts send it to you.
Miniature non-dispersive infrared (NDIR) methane sensor with UART and analog voltage output, designed to replace a catalytic gas sensor directly.
| Parameter | Value |
|---|---|
| Response time | T90 < 30 s |
| Average Current | <85mA |
| Characteristics | 1. High sensitivity, high resolution, fast response;2. Output method: UART, analog voltage signal;3. Temperature compensation, excellent linear output;4. Excellent stability, Long lifespan;5. Anti-poisons, anti-vapor interference;6. Can replace catalytic |
| Defense Grade | IP54 |
| Detection Gas | Methane (CH4) |
| Detection Principle | non-dispersive infrared (NDIR) principle |
| Detection range | 0~10% Vol optional |
| Interface Level | 3.0V |
| Life Time | >5 years |
| Measurement Range | 0~5.00% Vol; 0~10.00% Vol; 100%LEL |
| Model | MH-440D |
| Output Method | UART, analog voltage signal |
| Output signal | UART(3.0V) |
| Power, communication terminal Intrinsic safety | Ui=7.5VDC,Ii=265mA, Pi=0.5W,Ci=10μ F,Li=0mH |
| Resolution and accuracy | 0.01% Vol, 1%LEL |
| Size | Φ20×22.6mm |
| Sizes | Φ 20×22.6mm |
| Target | CH4 |
| Warm-Up Time | 3 min |
| Weight | 35g |
| Working Conditions | 3.6~5.0V DC(Need to be powered by safety barrier) |
| Working humidity | 0~95%RH (no condensation) |
| Working temperature | -20°C ~ 60°C |
| Working voltage | 3.6~5.0VDC (Need to be powered by safety barrier) |
Answers to the questions that the recorded characteristics of MH-440D can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Characteristics": 1. High sensitivity, high resolution, fast response;2. Output method: UART, analog voltage signal;3. Temperature compensation, excellent linear output;4. Excellent stability, Long lifespan;5. Anti-poisons, anti-vapor interference;6. Can replace catalytic.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Methane CH4 NDIR infrared gas sensor

NDIR Infrared Methane CH4 Sensor

Explosion-proof Methane Gas Detector Sensor with Audible-Visual Alarm

HENGKO flameproof combustible gas leak detection housing for atmospheric monitoring system

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MH-440D |
| Manufacturer | Winsen |
Methane Sensors
Natural gas (methane) detector with CAN Bus interface · Ref. : CL-20A-C
Price on request
Methane Sensors
MEMS combustible methane gas sensor · Ref. : RS-CH01
Price on request
Methane Sensors
MEMS methane CH4 gas detection sensor (breakout) · Ref. : SEN0565
Price on request
Methane Sensors
Flammable gas MOS sensor for propane, LPG and methane · Ref. : MQ-5B
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details