Overview. The Winsen MH-441D is a miniature NDIR (non-dispersive infrared) sensor, a universal intelligent gas sensor for detecting methane CH4 in air. It is an infrared methane sensor that can directly replace catalytic combustion sensors.
Main characteristics. Adjustable measuring range within 0-10 % vol for methane, with a resolution of 0.01 % vol. T90 response time below 30 s, warm-up time of 3 min and lifetime above 5 years. The sensor is independent of oxygen and offers high sensitivity, high resolution and good selectivity. Internal temperature compensation is provided by an integrated temperature sensor.
Interfaces and connectivity. UART-TTL output (3.3 V, compatible with 5 V) and 0.4-2.0 V output signal. The sensor is configured by program, with no sleep mode.
Power and environment. Operating voltage of 3.6 to 5 V DC, to be powered through a safety barrier. Average current below 85 mA (peak below 100 mA) at 5 V DC. Operating temperature from -20 °C to 60 °C, humidity from 0 to 95 % RH without condensation, IP54 protection rating. Dimensions Φ20 × 22.4 mm, weight 35 g. Intrinsic safety: Ui = 7.5 V DC, Ii = 265 mA, Pi = 0.5 W, Ci = 10 µF, Li = 0 µH.
Typical uses. Indoor air monitoring for HVAC and refrigeration, industrial process control and safety protection, agricultural and livestock applications. The sensor suits environments with combustible gases and explosion hazards, and tolerates high-density dust. It is resistant to poisoning and water vapour interference.
Integration. The sensor provides a UART digital output that can be read directly by a supervision system, in addition to the analogue output.
Target Gas — Molecular Formula — Measuring Range — Resolution — No. of decimal — Accuracy
Note
Warm-Up Time
3 min
Weight
35g
Working humidity
0~95%RH (no condensation)
Working temperature
-20°C ~ 60°C
Working voltage
3.6~5V DC (Require powered by safety barrier)
Alternatives and comparable products
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
1. High sensitivity, high resolution, fast response;2. Output method: UART, analog voltage signal;3. Temperature compensation, excellent linear output;4. Excellent stability, Long lifespan;5. Anti-poisons, anti-vapor interference;6. Can replace catalytic
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.