Flat surface semiconductor CO/CH4 gas sensor

- Detection range
- 50-1000ppm(CO),300-10000ppm(CH4)
- Characteristics
- High sensitivity to CO、CH4
- Detection Principle
- Semiconductor
- Environment Conditions
- -10℃~50℃
Flat surface semiconductor CO/CH4 gas sensor
Winsen MP-9 flat surface semiconductor gas sensor, sensitive to carbon monoxide and methane, intended for CO leakage alarms and portable CO detectors.
Winsen MP-9. CO/CH4 semiconductor flat surfaced gas sensor, model MP-9, detecting carbon monoxide and methane through the conductivity change of a metal oxide semiconductor. Main characteristics — The MP-9 has high sensitivity to CO and CH4, with detection ranges of 50-1000 ppm for CO and 300-10000 ppm for CH4. Its planar construction combines a heater and semiconductor material on a subminiature Al2O3 ceramic plate, encapsulated in a metal base and cap measuring φ9.4×7.5. Power and operation — The loop voltage is limited to 10 V DC. Operation relies on cyclic temperatures: high temperature heater voltage of 5±0.1 V and low temperature heater voltage of 1.5±0.1 V, with heater consumption at or below 240 mW. The sensor resistance is 105 Ω ±10 Ω at room temperature under standard test conditions. Environment — The sensor operates between -10 °C and 50 °C. Typical uses — The conductivity signal, which rises with CO and CH4 concentration, is converted into a gas concentration output through a simple circuit, which suits domestic CO leakage alarms, industrial CO gas alarms and portable CO detectors. Integration — The manufacturer states that the sensors have no sleeping mode, which can be set in the program if needed, and recommends ageing and calibration after the sensor stabilises according to the program and use conditions of the complete device. Manufacturer reference: MP-9, available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MP-9, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Characteristics | High sensitivity to CO、CH4 |
| Detection Principle | Semiconductor |
| Detection range | 50-1000ppm(CO),300-10000ppm(CH4) |
| Environment Conditions | -10℃~50℃ |
| Model | MP-9 |
| Sensor character under standard test conditions | 105Ω ±10Ω (room tem.) |
| Sensor Type | Flat Surfaced Semiconductor |
| Size | φ9.4×7.5 |
| Standard Circuit; Conditions | ≤ 10V DC |
| Standard Encapsulation | Metal Cap |
| Target | CO,CH4 |
| Target gas | CO, CH4 |
| Working Conditions | Loop Voltage:≤10V High temp.heater voltage:5±0.1V Low temp.heater voltage:1.5±0.1V Heater consumption:≤240mW |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for MP-9. For a missing document or a specific revision, our experts send it to you.
Winsen MP-9 flat surface semiconductor gas sensor, sensitive to carbon monoxide and methane, intended for CO leakage alarms and portable CO detectors.
| Parameter | Value |
|---|---|
| Characteristics | High sensitivity to CO、CH4 |
| Detection Principle | Semiconductor |
| Detection range | 50-1000ppm(CO),300-10000ppm(CH4) |
| Environment Conditions | -10℃~50℃ |
| Model | MP-9 |
| Sensor character under standard test conditions | 105Ω ±10Ω (room tem.) |
| Sensor Type | Flat Surfaced Semiconductor |
| Size | φ9.4×7.5 |
| Standard Circuit; Conditions | ≤ 10V DC |
| Standard Encapsulation | Metal Cap |
| Target | CO,CH4 |
| Target gas | CO, CH4 |
| Working Conditions | Loop Voltage:≤10V High temp.heater voltage:5±0.1V Low temp.heater voltage:1.5±0.1V Heater consumption:≤240mW |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Flat surface semiconductor CO/CH4 gas sensor

Methane CH4 Natural Gas Sensor

MOS Flammable Gas Sensor for Methane CH4 Detector

MOS Flammable Gas Sensor for Methane CH4

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MP-9 |
| Manufacturer | Winsen |
Methane Sensors
Natural gas (methane) detector with CAN Bus interface · Ref. : CL-20A-C
Price on request
Methane Sensors
MEMS combustible methane gas sensor · Ref. : RS-CH01
Price on request
Methane Sensors
MEMS methane CH4 gas detection sensor (breakout) · Ref. : SEN0565
Price on request
Methane Sensors
Flammable gas MOS sensor for propane, LPG and methane · Ref. : MQ-5B
Price on request