ZC01
Methane CH4 sensor module for mine use

- nominal working current — mA
- 100±10
- Flick Frequency — Hz — 1±0.2
- Rate in air 1:1, CH4 content.0%
- Flick Frequency — Hz — 2±0.2
- Rate in air1:1, CH4content >1.2%
- Alarm error — ≤ 0.1%
- CH4 content (0.5-1.0%)
Methane CH4 sensor module for mine use
Catalytic methane CH4 sensor module for mine alarm lamps and industrial flammable gas leak detection, driving a flashing lamp output above the alarm threshold.
Overview. The Winsen ZC01 is a catalytic methane CH4 sensor module designed for mine use. It controls a mining lamp that flashes when methane concentration exceeds the alarm point, and returns the lamp to normal lighting when the concentration falls back.
Main characteristics. Target: CH4 methane gas. Alarm point preset at the factory to 1.0 vol%. Alarm error less than or equal to 0.1%: CH4 content 0.5–1.0%. Response time less than or equal to 20 s. Zero stability ±0.1% CH4 with maximum zero drift per week. Sensor breakdown warning and zero calibration limit functions, avoiding continuous alarm or absence of alarm caused by a broken sensor.
Interfaces and signalling. Flicker frequency 1 ± 0.2 Hz in air at 1:1 ratio for 0% CH4 content, and 2 ± 0.2 Hz for CH4 content above 1.2%. Infrared remote adjustment mode.
Power and environment. Nominal voltage 3.1–5.0 V. Nominal working current 100 ± 10 mA, nominal control current less than or equal to 110 mA. Environment temperature 0–35 ℃, humidity less than or equal to 98% RH, atmosphere 80–110 kPa. H2S content limit less than or equal to 6 ppm.
Typical uses. Methane alarm mining lamps and industrial flammable gas leakage detectors.
Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ZC01, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Alarm error — ≤ 0.1% | CH4 content (0.5-1.0%) |
| Alarm point — vol — 1.0% | Preset before leaving factory |
| atmosphere | (80-110)Kpa |
| Detection Principle | Catalytic |
| Environment Humidity | ≤98%RH |
| Environment Temperature | (0-35)℃ |
| Flick Frequency — Hz — 1±0.2 | Rate in air 1:1, CH4 content.0% |
| Flick Frequency — Hz — 2±0.2 | Rate in air1:1, CH4content >1.2% |
| H2S content limit | ≤6ppm |
| Model | ZC01 |
| nominal control voltage — mA | ≤ 110 |
| Nominal Voltage (V) | 3.1-5.0 |
| nominal working current — mA | 100±10 |
| Response time — s | ≤ 20 |
| Target | CH4 methane gas |
| Zero stability — ±0.1%CH4 | Max zero drift every week |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ZC01. For a missing document or a specific revision, our experts send it to you.
Catalytic methane CH4 sensor module for mine alarm lamps and industrial flammable gas leak detection, driving a flashing lamp output above the alarm threshold.
| Parameter | Value |
|---|---|
| Alarm error — ≤ 0.1% | CH4 content (0.5-1.0%) |
| Alarm point — vol — 1.0% | Preset before leaving factory |
| atmosphere | (80-110)Kpa |
| Detection Principle | Catalytic |
| Environment Humidity | ≤98%RH |
| Environment Temperature | (0-35)℃ |
| Flick Frequency — Hz — 1±0.2 | Rate in air 1:1, CH4 content.0% |
| Flick Frequency — Hz — 2±0.2 | Rate in air1:1, CH4content >1.2% |
| H2S content limit | ≤6ppm |
| Model | ZC01 |
| nominal control voltage — mA | ≤ 110 |
| Nominal Voltage (V) | 3.1-5.0 |
| nominal working current — mA | 100±10 |
| Response time — s | ≤ 20 |
| Target | CH4 methane gas |
| Zero stability — ±0.1%CH4 | Max zero drift every week |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Methane CH4 sensor module for mine use

CH4 Methane Gas Sensor Module for Mine Use

Explosion-proof Methane Gas Detector Sensor with Audible-Visual Alarm

HENGKO flameproof combustible gas leak detection housing for atmospheric monitoring system

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ZC01 |
| Manufacturer | Winsen |
Methane Sensors
Natural gas (methane) detector with CAN Bus interface · Ref. : CL-20A-C
Price on request
Methane Sensors
MEMS combustible methane gas sensor · Ref. : RS-CH01
Price on request
Methane Sensors
MEMS methane CH4 gas detection sensor (breakout) · Ref. : SEN0565
Price on request
Methane Sensors
Flammable gas MOS sensor for propane, LPG and methane · Ref. : MQ-5B
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details