ZC02
Catalytic CH4 methane gas sensor module for mines

- nominal working current — mA
- 100±10
- Flick Frequency — Hz — 1±0.2
- Rate in air 1:1, CH4 content.0%
- Flick Frequency — Hz — 2±0.2
- Rate in air1:1, CH4content >1.2%
- Response time
- ≤20S
Catalytic CH4 methane gas sensor module for mines
CH4 methane gas sensor module with catalytic detection for mine use, intended for methane alarm mine lamps and industrial flammable gas leak detectors.
Overview. The Winsen ZC02 is a CH4 methane gas sensor module with catalytic detection for mine environments. It combines a high-stability catalytic gas sensor, a high-performance micro-computer processor and infrared remote adjustment, which makes the module reliable and simple to commission.
Main characteristics. Response time ≤ 20 s, alarm error ≤ 0.1% CH4 content (0.5-1.0%), factory-preset alarm point at 1.0% vol. Maximum zero drift of ±0.1% CH4 per week. Nominal working current of 100 ± 10 mA and nominal control current ≤ 110 mA.
Power and signalling. Nominal voltage 3.1 to 5.0 V. Flicker frequency of 1 ± 0.2 Hz in air (1:1 ratio, CH4 content 0%) and 2 ± 0.2 Hz when CH4 content exceeds 1.2%. The module includes sensor breakdown warning and zero calibration limit functions, avoiding continuous alarm or no alarm caused by a broken sensor.
Environmental conditions. Temperature 0 to 35 ℃, humidity ≤ 98% RH, atmosphere 80 to 110 kPa, H2S content limit 6 ppm.
Typical uses. Methane alarm mine lamps, which flicker the lighting when the concentration exceeds the alarm point, and industrial flammable gas leak detectors.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ZC02, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | ≤20S |
| Alarm error — ≤ 0.1% | CH4 content (0.5-1.0%) |
| Alarm point — vol — 1.0% | Preset before leaving factory |
| atmosphere | (80-110)Kpa |
| Detection Principle | Catalytic |
| Environment Humidity | ≤98%RH |
| Environment Temperature | (0-35)℃ |
| Flick Frequency — Hz — 1±0.2 | Rate in air 1:1, CH4 content.0% |
| Flick Frequency — Hz — 2±0.2 | Rate in air1:1, CH4content >1.2% |
| H2S content limit | ≤6ppm |
| Model | ZC02 |
| nominal control voltage — mA | ≤ 110 |
| Nominal Voltage (V) | 3.1-5.0 |
| nominal working current — mA | 100±10 |
| Response time — s | ≤ 20 |
| Target | CH4 methane gas |
| Zero stability — ±0.1%CH4 | Max zero drift every week |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ZC02. For a missing document or a specific revision, our experts send it to you.
CH4 methane gas sensor module with catalytic detection for mine use, intended for methane alarm mine lamps and industrial flammable gas leak detectors.
| Parameter | Value |
|---|---|
| Response time | ≤20S |
| Alarm error — ≤ 0.1% | CH4 content (0.5-1.0%) |
| Alarm point — vol — 1.0% | Preset before leaving factory |
| atmosphere | (80-110)Kpa |
| Detection Principle | Catalytic |
| Environment Humidity | ≤98%RH |
| Environment Temperature | (0-35)℃ |
| Flick Frequency — Hz — 1±0.2 | Rate in air 1:1, CH4 content.0% |
| Flick Frequency — Hz — 2±0.2 | Rate in air1:1, CH4content >1.2% |
| H2S content limit | ≤6ppm |
| Model | ZC02 |
| nominal control voltage — mA | ≤ 110 |
| Nominal Voltage (V) | 3.1-5.0 |
| nominal working current — mA | 100±10 |
| Response time — s | ≤ 20 |
| Target | CH4 methane gas |
| Zero stability — ±0.1%CH4 | Max zero drift every week |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Catalytic CH4 methane gas sensor module for mines

Methane CH4 Sensor Module for Mine Use

Explosion-proof Methane Gas Detector Sensor with Audible-Visual Alarm

HENGKO flameproof combustible gas leak detection housing for atmospheric monitoring system

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ZC02 |
| Manufacturer | Winsen |
Methane Sensors
Natural gas (methane) detector with CAN Bus interface · Ref. : CL-20A-C
Price on request
Methane Sensors
MEMS combustible methane gas sensor · Ref. : RS-CH01
Price on request
Methane Sensors
MEMS methane CH4 gas detection sensor (breakout) · Ref. : SEN0565
Price on request
Methane Sensors
Flammable gas MOS sensor for propane, LPG and methane · Ref. : MQ-5B
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details