MANUFACTURER

Kyoritsu

Japan

The first part of the Kyoritsu selection covers clamp meters; it also includes insulation resistance testers and installation and earth testers.

Kyoritsu offers a handheld digital multimeter with bar graph (KEW_1011) alongside a true-RMS digital multimeter with a current clamp (KEW_1021R).

  • KEW_1011 — Handheld digital multimeter with bar graph.
  • KEW_1021R — True-RMS digital multimeter with a current clamp.
  • KEW_1062 — Handheld industrial TRMS multimeter with 50,000 counts.
10Categories

Product families

Technologies

Matched from product names, summaries and categories.

Products

Page 2
Quote basket Action
KEW_3552 Kyoritsu Insulation resistance tester with memory and USB interface 7260 (Test lead with remote control switch); 7261A (Test lead with alligator clip); 8017A (Extension prod long); 9173 (Carrying case); 9121 (Shoulder strap); LR6(AA)x4; Instruction manualIEC 61010 CAT Ⅲ 600V / CAT Ⅳ 300V, IEC 61010-2-034; IEC61557-1,2,4 IEC61326-1,2-2 IEC60529(IP40)±2%rdg ±2dgt Status not stated Quote
KEW_3551 Kyoritsu 1000 V digital insulation resistance tester with 6 test voltages 7260 (Test lead with remote control switch); 7261A (Test lead with alligator clip); 8017A (Extension prod long); 9173 (Carrying case); 9121 (Shoulder strap); LR6(AA)x4 Instruction manualIEC61010 CATⅢ 600V / CAT IV 300V, IEC 61010-2-034; IEC61557-1,2,4 IEC61326-1,2-2 IEC60529(IP40)±2%rdg ±2dgt Status not stated Quote
KEW_6305 Kyoritsu Three-phase power analyser with clamp sensors 7141B (Voltage test lead set); 7148 (USB cable); 7170 (Power cord[EU]) or 7240(Power cord[UK]); 8326-02 (SD card [2GB]); 9125 (Carrying case); Battery (LR6)×6, Quick manualIEC 61010-1 CAT Ⅲ 600V– Status not stated Quote
KEW_3125B Kyoritsu High-voltage insulation tester 250 to 5000 V with PI and DAR diagnosis 7165B (Line probe); 7264A (Earth cord); 7265A (Guard cord); 8019 (Hook type prod); 9204 (Carrying case [Hard]); LR14 (Alkaline battery size C) × 8; Instruction manualIEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61326-1, 2-2±2%rdg±3dgt Status not stated Quote
KEW_1011 Kyoritsu Handheld digital multimeter with 6040 counts and bar graph ––– Status not stated Quote
KEW_1012 Kyoritsu Handheld multimeter with 6040 counts and true RMS ––– Status not stated Quote
KEW_6516 Kyoritsu Portable installation tester with ATT loop and RCD testing Mains test lead※1; 7281 (Test leads with remote control switch); 7246 (Distribution board test lead); 7228A (Earth resistance test leads); 8041 (Auxiliary earth spikes[2 spikes/1 set]); 9084 (Soft case); 9142 (Carrying case); 9151 (Shoulder strap); 9199 (Shoulder pad); 8212-USB (USB adapter); LR6(AA) × 8; Instruction manual; Calibration certificate–PSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification Status not stated Quote
KEW_2055 Kyoritsu AC/DC clamp meter 1000 A with voltage and resistance measurement 7066A (Test leads); 9094 (Carrying case) Instruction Manual–– Status not stated Quote
KEW_1061 Kyoritsu Handheld True RMS digital multimeter, 50,000 counts 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; B lank coverIEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC)– Status not stated Quote
KEW_1021R Kyoritsu True RMS Digital Multimeter with Clamp Sensor Input Wing-type holder; Flat-type holder; 7066A (Test leads); 8919 (Ceramic fuse [10A/600V]) × 1 (included); 9097 (Carrying case); R03 × 2; Instruction manualIEC 61010-1 CAT IV 300V / CAT III 600V; IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS)– Status not stated Quote
KEW_1030 Kyoritsu Compact handheld multimeter with LED light and auto ranging 9130 (Carrying case); LR44 × 2; Instruction manualIEC 61010-1 CAT III 600V; IEC 61010-031, IEC 61326-1– Status not stated Quote
KEW_1062 Kyoritsu Industrial handheld TRMS multimeter 50,000 counts 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; B lank coverIEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC)– Status not stated Quote
KEW_1020R Kyoritsu 1000 V AC/DC True RMS handheld multimeter Wing-type holder; 7066A (Test leads); R03 × 2; Instruction manualIEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V; IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS)– Status not stated Quote
KEW_3121B Kyoritsu 2500 V insulation resistance tester with auto-ranging 7165B (Line probe); 7264A (Earth cord); 7265A (Guard cord); 8019 (Hook type prod); 9182 (Carrying case[Hard]); LR14 (Alkaline battery size C) × 8; Instruction manualIEC 61010-1, IEC 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-2-034, IEC 61010-031, IEC 61326-1, 2-20.1 to 50GΩ : ±5%rdg; 0 to 0.1GΩ, 50GΩ to ∞ : ±10%rdg or 0.5% of scale length Status not stated Quote
KEW_4300 Kyoritsu Simplified 2-pole earth tester with AC/DC voltage measurement ––– Status not stated Quote
KEW_3122B Kyoritsu 5000 V insulation resistance tester with auto-ranging ––– Status not stated Quote
KEW_4202 Kyoritsu Earth and AC current tester with Bluetooth 8304 (Resister for operation check); 9167 (Carrying case[Hard]); LR6 x 4, Instruction manualIEC 61010-1 CAT Ⅳ 300V Pollution degree2; IEC 61010-2-032, IEC 61326 (EMC)– Status not stated Quote
KEW_3123A Kyoritsu 5000 V and 10000 V Digital Insulation Tester with Auto-Ranging 7165A (Line probe); 7224A (Earth cord); 7225A (Guard code); 8019 (Hook type prod); 9158 (Hard case); R6 (AA) × 8; Instruction manual–± 5% rdg Status not stated Quote
KEW_3127 Kyoritsu 5000 V digital insulation resistance tester with Bluetooth 7165A (Line probe); 7224A (Earth cord); 7225A (Guard cord); 8019 (Hook type prod); 8327EU (Power adapter 15V/1A); 9171 (Carrying case [Hard]); Instruction manual–±2%rdg±3dgt Status not stated Quote
KEW_2510 Kyoritsu DC milliampere clamp meter with memory and Bluetooth 8320 (AC adapter),; 9096 (Carrying case),; LR6(AA)x4, Instruction manualIEC 61010-1 Pollution degree 2 IEC 61010-2-032,; IEC 61326-1(EMC) IEC 60529 IP40, EN50581(RoHS)– Status not stated Quote
KEW_3124A Kyoritsu High-voltage insulation resistance tester, 10 kV variable test voltage 7082 (Leads for recorder); 7083 (Leads for battery charging); 7084 (Earth and guard leads); 8266 (Battery charger[120V]) or 8267 (Battery charger[220V]) or 8264A (Battery charger[AU]); 9176 (Carrying case [Hard]); 8268 (Ni-MH rechargeable battery × 8); Instruction manual–– Status not stated Quote
KEW_2500 Kyoritsu DC clamp meter 0.01 to 120 mA, Ø 6 mm jaw 9096 (Carrying case); LR6 (AA) × 4, Instruction ManualIEC 61010-1 Pollution degree 2; IEC 61010-2-032, IEC 61326-1(EMC); IEC 60529 IP40, EN50581(RoHS)– Status not stated Quote
MODEL_5510 Kyoritsu Waterproof handheld infrared thermometer IP67 LR03(AAA) x 2; Instruction Manual; Strap–– Status not stated Quote
MODEL_8128 Kyoritsu Clamp-on current transformer, 50 mV/5 A output 9095 (Carrying case); Instruction manual, Cable markerIEC 61010-1, IEC 61010-2-032:2002 CAT III 300V pollution degree 2, IEC 61326±0.5%rdg±0.1mV (50/60Hz); ±1.0%rdg±0.2mV (40Hz to 1kHz) Status not stated Quote
MODEL_8004 Kyoritsu Multi-tran current transformer adaptor for clamp meters 9022(Carrying Case)–±3% of full scale Status not stated Quote
MODEL_8006 Kyoritsu AC clamp adaptor for currents up to 1500 A 9022 (Carrying Case); Instruction Manual–±3%rdg+1A [45 - 65Hz] (0 - 1000A); ±5%rdg [45 - 65Hz] (1000 - 1500A) Status not stated Quote
MODEL_8008 Kyoritsu AC current transformer adaptor for clamp meters, 3000 A ––– Status not stated Quote
MODEL_8302A Kyoritsu Recorder adapter with 1 mV / 1 µA output ––– Status not stated Quote
8112BNC Kyoritsu AC clamp adaptor with BNC output for oscilloscopes 9095 (Carrying Case); Instruction Manual–– Status not stated Quote
MODEL_8324A Kyoritsu Recorder adapter, 10 mV / 1 µA output ––– Status not stated Quote
7313-RED Kyoritsu Retractable red test prod, CAT IV 600 V rated ––– Status not stated Quote
7313-GRN Kyoritsu Retractable green test probe with auto-slide cover ––– Status not stated Quote
7313-WHT Kyoritsu Retractable auto-slide cover test probe, white ––– Status not stated Quote
MODEL_8112 Kyoritsu AC current clamp adapter for digital multimeters 9095 (Carrying Case); Instruction Manual–– Status not stated Quote
MODEL_8113 Kyoritsu AC/DC current clamp adaptor 7061 (Output cords); R6 (AA) × 2; 9055 (Carrying Case); Instruction Manual–– Status not stated Quote
MODEL_8103 Kyoritsu AC clamp current probe 15/30/150/300/1500 A, 60 mm aperture ––±2% of Output Status not stated Quote
MODEL_8104 Kyoritsu AC clamp current probe 30 to 3000 A ––±2% of Output Status not stated Quote
7313-BLU Kyoritsu Retractable auto-slide test prod, blue ––– Status not stated Quote
MODEL_8127 Kyoritsu AC current clamp sensor 100 A, 500 mV output 9095 (Carrying case); Instruction manual, Cable markerIEC 61010-1, IEC 61010-2-032:2002 CAT III 300V pollution degree 2, IEC 61326±0.5%rdg±0.1mV (50/60Hz); ±1.0%rdg±0.2mV (40Hz to 1kHz) Status not stated Quote
MODEL_5500 Kyoritsu Portable infrared thermometer with laser sighting, -40 to 500 °C LR6 × 2; Soft Vinyl Case; Instruction Manual–– Status not stated Quote
MODEL_8126 Kyoritsu AC 200 A voltage-output clamp meter 9095 (Carrying case); Instruction manual, Cable markerIEC 61010-1, IEC 61010-2-032:2002 CAT III 600V pollution degree 2, IEC 61326±0.5%rdg±0.1mV (50/60Hz); ±1.0%rdg±0.2mV (40Hz to 1kHz) Status not stated Quote
MODEL_8125 Kyoritsu AC clamp meter with 500 A voltage output 9095 (Carrying case); Instruction manual, Cable markerIEC 61010-1, IEC 61010-2-032:2002 CAT III 600V pollution degree 2, IEC 61326±0.5%rdg±0.1mV (50/60Hz); ±1.0%rdg±0.2mV (40Hz to 1kHz) Status not stated Quote
MODEL_8141 Kyoritsu AC clamp meter for 1000 A current measurement 9095 (Portable case), Instruction manualIEC 61010-1, IEC 61010-2-032, CAT III 300V pollution degree 2±1.0%rdg±0.1mV (50/60Hz) ±2.0%rdg±0.1mV (40Hz - 1kHz) Status not stated Quote
MODEL_8124 Kyoritsu AC 1000 A voltage-output clamp meter 9094 (Carrying case); Instruction manual, Cable markerIEC 61010-1, IEC 61010-2-032 CAT III 600V pollution degree 2, IEC 61326±0.5%rdg±0.2mV (50/60Hz); ±1.5%rdg±0.4mV (40Hz to 1kHz) Status not stated Quote
MODEL_8143 Kyoritsu AC 1000 A clamp meter with voltage output, Ø 68 mm jaws 9094 (Portable case), Instruction manualIEC 61010-1, IEC 61010-2-032, CAT III 300V pollution degree 2±1.0%rdg±0.1mV (50/60Hz) ±2.0%rdg±0.1mV (40Hz - 1kHz) Status not stated Quote
MODEL_8142 Kyoritsu AC clamp meter with voltage output, Ø40 mm 9095 (Portable case), Instruction manualIEC 61010-1, IEC 61010-2-032, CAT III 300V pollution degree 2±1.0%rdg±0.1mV (50/60Hz) ±2.0%rdg±0.1mV (40Hz - 1kHz) Status not stated Quote
MODEL_3321A Kyoritsu Analog insulation tester 250/500/1000 V with 600 V AC voltmeter ––– Status not stated Quote
3322A/3323A Kyoritsu Insulation Resistance Tester 125 V 250 V 500 V 7150A (Remote control switch set); Shoulder Strap; R6 (AA) × 6; Instruction Manual–±5% of Indicated Value Status not stated Quote
MODEL_2608A Kyoritsu AC 300 A clamp meter with resistance measurement ––– Status not stated Quote
MODEL_2431 Kyoritsu AC clamp meter with 24 mm jaw ––– Status not stated Quote

Manufacturers similar to Kyoritsu

Makers with the most products in the same categories.

Frequently asked questions about Kyoritsu

Which Kyoritsu products does Atlas Electronics list?

Products in 10 categories, mainly Clamp Meters, Insulation Resistance Testers, Installation and Earth Testers.

How do I get a price for a Kyoritsu product?

Prices and lead times are given on quotation: use "Request a quote" on a product page, or add several references to your quote request.

Where is Kyoritsu based?

Kyoritsu is based in Japan.