The first part of the Kyoritsu selection covers clamp meters; it also includes insulation resistance testers and installation and earth testers.
Kyoritsu offers a handheld digital multimeter with bar graph (KEW_1011) alongside a true-RMS digital multimeter with a current clamp (KEW_1021R).
- KEW_1011 — Handheld digital multimeter with bar graph.
- KEW_1021R — True-RMS digital multimeter with a current clamp.
- KEW_1062 — Handheld industrial TRMS multimeter with 50,000 counts.
Product families
- Clamp Meters 51 products
- Insulation Resistance Testers 42 products
- Installation and Earth Testers 31 products
- Handheld Multimeters 25 products
- Submeters 14 products
- Current Probes 9 products
- Test Leads and Probes 7 products
- Current Transformers Sensors 4 products
- Infrared Thermometers 3 products
- Rogowski Coils 1 product
Technologies
Matched from product names, summaries and categories.
Products
| Quote basket | Action | |||||||
|---|---|---|---|---|---|---|---|---|
| KEW_3552 | Kyoritsu | Insulation resistance tester with memory and USB interface | 7260 (Test lead with remote control switch); 7261A (Test lead with alligator clip); 8017A (Extension prod long); 9173 (Carrying case); 9121 (Shoulder strap); LR6(AA)x4; Instruction manual | IEC 61010 CAT Ⅲ 600V / CAT Ⅳ 300V, IEC 61010-2-034; IEC61557-1,2,4 IEC61326-1,2-2 IEC60529(IP40) | ±2%rdg ±2dgt | Status not stated | Quote | |
| KEW_3551 | Kyoritsu | 1000 V digital insulation resistance tester with 6 test voltages | 7260 (Test lead with remote control switch); 7261A (Test lead with alligator clip); 8017A (Extension prod long); 9173 (Carrying case); 9121 (Shoulder strap); LR6(AA)x4 Instruction manual | IEC61010 CATⅢ 600V / CAT IV 300V, IEC 61010-2-034; IEC61557-1,2,4 IEC61326-1,2-2 IEC60529(IP40) | ±2%rdg ±2dgt | Status not stated | Quote | |
| KEW_6305 | Kyoritsu | Three-phase power analyser with clamp sensors | 7141B (Voltage test lead set); 7148 (USB cable); 7170 (Power cord[EU]) or 7240(Power cord[UK]); 8326-02 (SD card [2GB]); 9125 (Carrying case); Battery (LR6)×6, Quick manual | IEC 61010-1 CAT Ⅲ 600V | – | Status not stated | Quote | |
| KEW_3125B | Kyoritsu | High-voltage insulation tester 250 to 5000 V with PI and DAR diagnosis | 7165B (Line probe); 7264A (Earth cord); 7265A (Guard cord); 8019 (Hook type prod); 9204 (Carrying case [Hard]); LR14 (Alkaline battery size C) × 8; Instruction manual | IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61326-1, 2-2 | ±2%rdg±3dgt | Status not stated | Quote | |
| KEW_1011 | Kyoritsu | Handheld digital multimeter with 6040 counts and bar graph | – | – | – | Status not stated | Quote | |
| KEW_1012 | Kyoritsu | Handheld multimeter with 6040 counts and true RMS | – | – | – | Status not stated | Quote | |
| KEW_6516 | Kyoritsu | Portable installation tester with ATT loop and RCD testing | Mains test lead※1; 7281 (Test leads with remote control switch); 7246 (Distribution board test lead); 7228A (Earth resistance test leads); 8041 (Auxiliary earth spikes[2 spikes/1 set]); 9084 (Soft case); 9142 (Carrying case); 9151 (Shoulder strap); 9199 (Shoulder pad); 8212-USB (USB adapter); LR6(AA) × 8; Instruction manual; Calibration certificate | – | PSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification | Status not stated | Quote | |
| KEW_2055 | Kyoritsu | AC/DC clamp meter 1000 A with voltage and resistance measurement | 7066A (Test leads); 9094 (Carrying case) Instruction Manual | – | – | Status not stated | Quote | |
| KEW_1061 | Kyoritsu | Handheld True RMS digital multimeter, 50,000 counts | 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; B lank cover | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC) | – | Status not stated | Quote | |
| KEW_1021R | Kyoritsu | True RMS Digital Multimeter with Clamp Sensor Input | Wing-type holder; Flat-type holder; 7066A (Test leads); 8919 (Ceramic fuse [10A/600V]) × 1 (included); 9097 (Carrying case); R03 × 2; Instruction manual | IEC 61010-1 CAT IV 300V / CAT III 600V; IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS) | – | Status not stated | Quote | |
| KEW_1030 | Kyoritsu | Compact handheld multimeter with LED light and auto ranging | 9130 (Carrying case); LR44 × 2; Instruction manual | IEC 61010-1 CAT III 600V; IEC 61010-031, IEC 61326-1 | – | Status not stated | Quote | |
| KEW_1062 | Kyoritsu | Industrial handheld TRMS multimeter 50,000 counts | 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; B lank cover | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC) | – | Status not stated | Quote | |
| KEW_1020R | Kyoritsu | 1000 V AC/DC True RMS handheld multimeter | Wing-type holder; 7066A (Test leads); R03 × 2; Instruction manual | IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V; IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS) | – | Status not stated | Quote | |
| KEW_3121B | Kyoritsu | 2500 V insulation resistance tester with auto-ranging | 7165B (Line probe); 7264A (Earth cord); 7265A (Guard cord); 8019 (Hook type prod); 9182 (Carrying case[Hard]); LR14 (Alkaline battery size C) × 8; Instruction manual | IEC 61010-1, IEC 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-2-034, IEC 61010-031, IEC 61326-1, 2-2 | 0.1 to 50GΩ : ±5%rdg; 0 to 0.1GΩ, 50GΩ to ∞ : ±10%rdg or 0.5% of scale length | Status not stated | Quote | |
| KEW_4300 | Kyoritsu | Simplified 2-pole earth tester with AC/DC voltage measurement | – | – | – | Status not stated | Quote | |
| KEW_3122B | Kyoritsu | 5000 V insulation resistance tester with auto-ranging | – | – | – | Status not stated | Quote | |
| KEW_4202 | Kyoritsu | Earth and AC current tester with Bluetooth | 8304 (Resister for operation check); 9167 (Carrying case[Hard]); LR6 x 4, Instruction manual | IEC 61010-1 CAT Ⅳ 300V Pollution degree2; IEC 61010-2-032, IEC 61326 (EMC) | – | Status not stated | Quote | |
| KEW_3123A | Kyoritsu | 5000 V and 10000 V Digital Insulation Tester with Auto-Ranging | 7165A (Line probe); 7224A (Earth cord); 7225A (Guard code); 8019 (Hook type prod); 9158 (Hard case); R6 (AA) × 8; Instruction manual | – | ± 5% rdg | Status not stated | Quote | |
| KEW_3127 | Kyoritsu | 5000 V digital insulation resistance tester with Bluetooth | 7165A (Line probe); 7224A (Earth cord); 7225A (Guard cord); 8019 (Hook type prod); 8327EU (Power adapter 15V/1A); 9171 (Carrying case [Hard]); Instruction manual | – | ±2%rdg±3dgt | Status not stated | Quote | |
| KEW_2510 | Kyoritsu | DC milliampere clamp meter with memory and Bluetooth | 8320 (AC adapter),; 9096 (Carrying case),; LR6(AA)x4, Instruction manual | IEC 61010-1 Pollution degree 2 IEC 61010-2-032,; IEC 61326-1(EMC) IEC 60529 IP40, EN50581(RoHS) | – | Status not stated | Quote | |
| KEW_3124A | Kyoritsu | High-voltage insulation resistance tester, 10 kV variable test voltage | 7082 (Leads for recorder); 7083 (Leads for battery charging); 7084 (Earth and guard leads); 8266 (Battery charger[120V]) or 8267 (Battery charger[220V]) or 8264A (Battery charger[AU]); 9176 (Carrying case [Hard]); 8268 (Ni-MH rechargeable battery × 8); Instruction manual | – | – | Status not stated | Quote | |
| KEW_2500 | Kyoritsu | DC clamp meter 0.01 to 120 mA, Ø 6 mm jaw | 9096 (Carrying case); LR6 (AA) × 4, Instruction Manual | IEC 61010-1 Pollution degree 2; IEC 61010-2-032, IEC 61326-1(EMC); IEC 60529 IP40, EN50581(RoHS) | – | Status not stated | Quote | |
| MODEL_5510 | Kyoritsu | Waterproof handheld infrared thermometer IP67 | LR03(AAA) x 2; Instruction Manual; Strap | – | – | Status not stated | Quote | |
| MODEL_8128 | Kyoritsu | Clamp-on current transformer, 50 mV/5 A output | 9095 (Carrying case); Instruction manual, Cable marker | IEC 61010-1, IEC 61010-2-032:2002 CAT III 300V pollution degree 2, IEC 61326 | ±0.5%rdg±0.1mV (50/60Hz); ±1.0%rdg±0.2mV (40Hz to 1kHz) | Status not stated | Quote | |
| MODEL_8004 | Kyoritsu | Multi-tran current transformer adaptor for clamp meters | 9022(Carrying Case) | – | ±3% of full scale | Status not stated | Quote | |
| MODEL_8006 | Kyoritsu | AC clamp adaptor for currents up to 1500 A | 9022 (Carrying Case); Instruction Manual | – | ±3%rdg+1A [45 - 65Hz] (0 - 1000A); ±5%rdg [45 - 65Hz] (1000 - 1500A) | Status not stated | Quote | |
| MODEL_8008 | Kyoritsu | AC current transformer adaptor for clamp meters, 3000 A | – | – | – | Status not stated | Quote | |
| MODEL_8302A | Kyoritsu | Recorder adapter with 1 mV / 1 µA output | – | – | – | Status not stated | Quote | |
| 8112BNC | Kyoritsu | AC clamp adaptor with BNC output for oscilloscopes | 9095 (Carrying Case); Instruction Manual | – | – | Status not stated | Quote | |
| MODEL_8324A | Kyoritsu | Recorder adapter, 10 mV / 1 µA output | – | – | – | Status not stated | Quote | |
| 7313-RED | Kyoritsu | Retractable red test prod, CAT IV 600 V rated | – | – | – | Status not stated | Quote | |
| 7313-GRN | Kyoritsu | Retractable green test probe with auto-slide cover | – | – | – | Status not stated | Quote | |
| 7313-WHT | Kyoritsu | Retractable auto-slide cover test probe, white | – | – | – | Status not stated | Quote | |
| MODEL_8112 | Kyoritsu | AC current clamp adapter for digital multimeters | 9095 (Carrying Case); Instruction Manual | – | – | Status not stated | Quote | |
| MODEL_8113 | Kyoritsu | AC/DC current clamp adaptor | 7061 (Output cords); R6 (AA) × 2; 9055 (Carrying Case); Instruction Manual | – | – | Status not stated | Quote | |
| MODEL_8103 | Kyoritsu | AC clamp current probe 15/30/150/300/1500 A, 60 mm aperture | – | – | ±2% of Output | Status not stated | Quote | |
| MODEL_8104 | Kyoritsu | AC clamp current probe 30 to 3000 A | – | – | ±2% of Output | Status not stated | Quote | |
| 7313-BLU | Kyoritsu | Retractable auto-slide test prod, blue | – | – | – | Status not stated | Quote | |
| MODEL_8127 | Kyoritsu | AC current clamp sensor 100 A, 500 mV output | 9095 (Carrying case); Instruction manual, Cable marker | IEC 61010-1, IEC 61010-2-032:2002 CAT III 300V pollution degree 2, IEC 61326 | ±0.5%rdg±0.1mV (50/60Hz); ±1.0%rdg±0.2mV (40Hz to 1kHz) | Status not stated | Quote | |
| MODEL_5500 | Kyoritsu | Portable infrared thermometer with laser sighting, -40 to 500 °C | LR6 × 2; Soft Vinyl Case; Instruction Manual | – | – | Status not stated | Quote | |
| MODEL_8126 | Kyoritsu | AC 200 A voltage-output clamp meter | 9095 (Carrying case); Instruction manual, Cable marker | IEC 61010-1, IEC 61010-2-032:2002 CAT III 600V pollution degree 2, IEC 61326 | ±0.5%rdg±0.1mV (50/60Hz); ±1.0%rdg±0.2mV (40Hz to 1kHz) | Status not stated | Quote | |
| MODEL_8125 | Kyoritsu | AC clamp meter with 500 A voltage output | 9095 (Carrying case); Instruction manual, Cable marker | IEC 61010-1, IEC 61010-2-032:2002 CAT III 600V pollution degree 2, IEC 61326 | ±0.5%rdg±0.1mV (50/60Hz); ±1.0%rdg±0.2mV (40Hz to 1kHz) | Status not stated | Quote | |
| MODEL_8141 | Kyoritsu | AC clamp meter for 1000 A current measurement | 9095 (Portable case), Instruction manual | IEC 61010-1, IEC 61010-2-032, CAT III 300V pollution degree 2 | ±1.0%rdg±0.1mV (50/60Hz) ±2.0%rdg±0.1mV (40Hz - 1kHz) | Status not stated | Quote | |
| MODEL_8124 | Kyoritsu | AC 1000 A voltage-output clamp meter | 9094 (Carrying case); Instruction manual, Cable marker | IEC 61010-1, IEC 61010-2-032 CAT III 600V pollution degree 2, IEC 61326 | ±0.5%rdg±0.2mV (50/60Hz); ±1.5%rdg±0.4mV (40Hz to 1kHz) | Status not stated | Quote | |
| MODEL_8143 | Kyoritsu | AC 1000 A clamp meter with voltage output, Ø 68 mm jaws | 9094 (Portable case), Instruction manual | IEC 61010-1, IEC 61010-2-032, CAT III 300V pollution degree 2 | ±1.0%rdg±0.1mV (50/60Hz) ±2.0%rdg±0.1mV (40Hz - 1kHz) | Status not stated | Quote | |
| MODEL_8142 | Kyoritsu | AC clamp meter with voltage output, Ø40 mm | 9095 (Portable case), Instruction manual | IEC 61010-1, IEC 61010-2-032, CAT III 300V pollution degree 2 | ±1.0%rdg±0.1mV (50/60Hz) ±2.0%rdg±0.1mV (40Hz - 1kHz) | Status not stated | Quote | |
| MODEL_3321A | Kyoritsu | Analog insulation tester 250/500/1000 V with 600 V AC voltmeter | – | – | – | Status not stated | Quote | |
| 3322A/3323A | Kyoritsu | Insulation Resistance Tester 125 V 250 V 500 V | 7150A (Remote control switch set); Shoulder Strap; R6 (AA) × 6; Instruction Manual | – | ±5% of Indicated Value | Status not stated | Quote | |
| MODEL_2608A | Kyoritsu | AC 300 A clamp meter with resistance measurement | – | – | – | Status not stated | Quote | |
| MODEL_2431 | Kyoritsu | AC clamp meter with 24 mm jaw | – | – | – | Status not stated | Quote |
Manufacturers similar to Kyoritsu
Makers with the most products in the same categories.
Frequently asked questions about Kyoritsu
Which Kyoritsu products does Atlas Electronics list?
Products in 10 categories, mainly Clamp Meters, Insulation Resistance Testers, Installation and Earth Testers.
How do I get a price for a Kyoritsu product?
Prices and lead times are given on quotation: use "Request a quote" on a product page, or add several references to your quote request.
Where is Kyoritsu based?
Kyoritsu is based in Japan.