MANUFACTURER

Kyoritsu

Japan

The first part of the Kyoritsu selection covers clamp meters; it also includes insulation resistance testers and installation and earth testers.

Kyoritsu offers a handheld digital multimeter with bar graph (KEW_1011) alongside a true-RMS digital multimeter with a current clamp (KEW_1021R).

  • KEW_1011 — Handheld digital multimeter with bar graph.
  • KEW_1021R — True-RMS digital multimeter with a current clamp.
  • KEW_1062 — Handheld industrial TRMS multimeter with 50,000 counts.
10Categories
440Documents

Product families

Technologies

Matched from product names, summaries and categories.

Products

Page 1
Quote basket Action
KEW_8177 Kyoritsu AC clamp current sensor 10 A, 500 mV output 9095 (Carrying case); Instruction manualIEC 61010-1, IEC 61010-2-032 CAT Ⅲ 300V Pollution degree 2, IEC 61326-1±1.0%rdg±0.025mV (40 to 70Hz); ±4.0%rdg±0.025mV (30Hz to 5kHz, with inputs of 100mA or more)Ø 40mm128(L) × 81(W) × 36(D)mm Status not stated Quote
KEW_8161 Kyoritsu AC clamp sensor for digital multimeter Instruction manualIEC 61010-1 CAT III 300V pollution degree 2, IEC 61010-2-032±2.0%rdg±3.0mV (45 to 65Hz) ±2.5%rdg±3.0mV (65Hz to 1kHz)Ø 2497(L) × 59(W) × 26(D) mm Status not stated Quote
KEW_8178 Kyoritsu AC clamp meter with 500 mV output for KEW 5050 leakage 9094 (Carrying case), Instruction manualIEC 61010-1, IEC 61010-2-032 CAT Ⅲ 300V Pollution degree 2, IEC 61326-1±1.0%rdg±0.025mV (40 to 70Hz); ±4.0%rdg±0.025mV (30Hz to 5kHz, with inputs of 100mA or more)Ø 68mm186(L) × 129(W) × 53(D)mm Status not stated Quote
KEW_8129 Kyoritsu Flexible air-core AC current probe up to 3000 A 8129-01 (for 1ch) Instruction Manual, 7199 (Output Cable) x1, 9137 (Carrying Case) 8129-02 (for 2ch) Instruction Manual, 7199 (Output Cable) x2, 9137 (Carrying Case) 8129-03 (for 3ch)Instruction Manual, 7199 (Output Cable) x3, 9137 (Carrying Case)IEC 61010-1, IEC 61010-2-032 CAT III 600V Pollution degree2, IEC 61326±1.0%rdg (45 - 65Hz)max.Ø 150mm111(L) x 61(W) x 43(D) mm (except for protrusions) Status not stated Quote
KEW_8130 Kyoritsu AC clamp meter with air core coil, 1000 A 9095 (Carrying case); Instruction manual, Cable markerIEC 61010-1, IEC 61010-2-030; IEC 61010-2-032 CAT IV 300V / CAT III 600V Pollution degree 2; IEC 61326±0.8%rdg±0.2mV (45Hz to 65Hz); ±1.5%rdg±0.4mV (40Hz to 1kHz)max.Ø 110mm– Status not stated Quote
KEW_8135 Kyoritsu Flexible Rogowski coil current sensor 50 A AC 9095 (Carrying case); Instruction manual, Cable markerIEC 61010-1, IEC 61010-2-032 CAT IV 300V / CAT III 600V Pollution degree 2, IEC 61326±1.0%rdg±0.5mV (45 to 65Hz) (0 to 50A); ±1.5%rdg±0.5mV (40 to 300Hz) (0 to 20A); ±1.5%rdg±0.5mV (300Hz to 1kHz) (0 to 5A)φ 75 mm (max)65(L)×24(W)×22(D)mm Status not stated Quote
KEW_8121 Kyoritsu AC 100 A clamp meter with voltage output 9095 (Carrying case); Instruction manual, Cable markerIEC 61010-1, IEC 61010-2-032 CAT III 300V pollution degree 2, IEC 61326±2.0%rdg±0.3mV (50/60Hz); ±3.0%rdg±0.5mV (40Hz to 1kHz)Ø 24mm97(L) x 59(W) x 26(D) mm Status not stated Quote
KEW_8115 Kyoritsu AC/DC current clamp sensor for digital multimeters 9095 (Carrying case); LR03×2, Instruction manualIEC 61010-1 CAT III 300V Pollution degree 2, IEC 61010-2-032, IEC 61326-1–Max. Ø 12mm127(L)×42(W)×22(D) mm Status not stated Quote
KEW_2210R Kyoritsu Flexible clamp meter with TRMS measurement 9174 (Carrying case); LR03(AAA)×2, Insruction manualIEC 61010-1, IEC 61010-2-032; CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree 2; IEC 61326-1(EMC), IEC 60529 IP40, EN50581(RoHS)±3%rdg±5dgt [45 to 500Hz]; (At the center of the circle formed by the flexible sensor)φ 150mm max.120(L)×70(W)×26(D):Display unit; φ 8.5mm approx.:Cable diameter; 1.8m : Cable length Status not stated Quote
KEW_2117R Kyoritsu True RMS 1000 A clamp meter with fully safety jaws 7066A (Test leads); 9079 (Carrying case); R03 (AAA) × 2, Instruction ManualIEC 61010-1 CAT IV 300V / CAT III 600V Pollution degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033,; IEC 61326-2-2(EMC), IEC 60529 IP 40, EN50581(RoHS)–φ 33mm max.– Status not stated Quote
KEW_2204R Kyoritsu Flexible AC Clamp Meter with True RMS 9174 (Carrying case); LR03(AAA)×2, Insruction manualIEC 61010-1, IEC 61010-2-032; CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree 2; IEC 61326-1(EMC), IEC 60529 IP40, EN50581(RoHS)±3%rdg±5dgt [45 to 500Hz]; (At the center of the circle formed by the flexible sensor)φ 70mm max.120(L)×70(W)×26(D):Display unit; φ 5.5mm approx.:Cable diameter; 1.8m : Cable length Status not stated Quote
KEW_2127R Kyoritsu Fully insulated TRMS clamp meter 7066A (Test leads); 9079 (Carrying case); R03(AAA)×2 Instruction manualIEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033,; IEC 61326-2-2(EMC), IEC 60529 IP40, EN 50581(RoHS)–φ 33mm max.– Status not stated Quote
KEW_3025A Kyoritsu High Voltage Insulation Resistance Tester 2500 V 7165A (Line probe); 7264 (Earth cord); 7265 (Guard cord); 8019 (Hook type prod); 9180 (Carrying case [Hard]); LR14 (Alkaline battery size C) × 8; Instruction manualIEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61326-1, 2-2±5%rdg±3dgt–177 (L) × 226 (W) × 100 (D) mm; 300 (L) × 315 (W) × 125 (D) mm (Carrying case [Hard]) Status not stated Quote
KEW_6016 Kyoritsu Multifunction installation tester with loop and RCD testing 7188A (Distribution board fuse test lead set) 7281 (Test leads with remote control switch) 7218A (Power cord [EU]) (*6) 7228A (Earth resistance test leads) 8032 (Auxiliary earth spikes) 8212-USB (USB adaptor with KEW Report (Software)) 9084 (Cord case) 9142 (Carrying case) 9121 (Shoulder strap) Cord case, Buckle, Battery, Instruction manualIEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031, IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC)––136(L) X 235(W) X 114(D)mm Status not stated Quote
KEW_2009R Kyoritsu TRMS AC/DC clamp meter up to 2000 A 7107A (Test leads); 9094 (Carrying case); R6 (AA) × 2,; Instruction ManualIEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61326-2-2–φ 55mm max.– Status not stated Quote
KEW_3023A Kyoritsu 1000 V digital insulation resistance tester with continuity test 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction ManualIEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)±2%rdg±6dgt–– Status not stated Quote
KEW_2003A Kyoritsu AC/DC clamp meter up to 2000 A 7107A (Test leads); 9094 (Carrying Case); R6 (AA) × 2, Instruction Manual––Ø 55mm max.– Status not stated Quote
KEW_6310 Kyoritsu Three-phase power quality analyzer 7141B (Voltage test lead set) 7148 (USB cable) 7170 (Power cord) 9125 (Carrying case) 8307 (Compact flash card 128MB) 8319 (CF Card reader) Input terminal plate (6-kind) Alkaline size AA battery (LR6) × 6 PQA MASTER (PC Software) Quick manual Cable marker × 32IEC 61010-1 CAT III 600V Pollution degree 2 IEC 61010-031, IEC 61326±0.3%rdg±0.2%f.s. (sine wave, 45 - 65Hz)–175(L)×120(W)×68(D) mm Status not stated Quote
KEW_2056R Kyoritsu AC/DC clamp meter with voltage and capacitance measurement 7066A (Test leads); 9094 (Carrying case) Instruction Manual––Ø 40mm– Status not stated Quote
KEW_3125A Kyoritsu High voltage insulation tester 250 V to 5000 V 7165A (Line probe); 7264 (Earth cord); 7265 (Guard cord); 8019 (Hook type prod); 9181 (Carrying case [Hard]); LR14 (Alkaline battery size C) × 8; Instruction manualIEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61326-1, 2-2±2%rdg±3dgt–177 (L) × 226 (W) × 100 (D) mm; 300 (L) × 315 (W) × 125 (D) mm (Carrying case [Hard]) Status not stated Quote
KEW_3022A Kyoritsu Digital insulation resistance tester with 4 test voltages 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction ManualIEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)5MΩ (50/100/250V) 50MΩ (500V)–– Status not stated Quote
KEW_3121A Kyoritsu 2500 V DC Insulation Tester with Auto-Ranging 7165A (Line probe) (3m) 7224A (Earth cord) (1.5m) 7225A (Guard code) (1.5m) 9158 (Hard case) R6 (AA) × 8 Instruction manual–± 5% rdg–200 (L) × 140 (W) × 80 (D) mm Status not stated Quote
KEW_3122A Kyoritsu High voltage insulation tester, 5000 V DC 7165A (Line probe) (3m) 7224A (Earth cord) (1.5m) 7225A (Guard code) (1.5m) 9158 (Hard case) R6 (AA) × 8 Instruction manual–± 5% rdg–200 (L) × 140 (W) × 80 (D) mm Status not stated Quote
KEW_3021A Kyoritsu Digital insulation tester 125 to 1000 V with continuity test 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction ManualIEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)±2%rdg±6dgt–– Status not stated Quote
KEW_2200 Kyoritsu 1000 A AC clamp meter with DMM functions and continuity buzzer 7107A (Test leads),; 9160 (Carrying case),; R03 (AAA) × 2, Instruction ManualIEC 61010-1 CAT III 600V Pollution degree 2 (AC A),; CAT III 300V / CAT II 600V Pollution degree 2 (AC/DC V); IEC 61010-031, IEC 61010-2-032, IEC 61326 (EMC)–φ 33mm max.– Status not stated Quote
KEW_3023 Kyoritsu Digital insulation tester with 4 test voltages 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction ManualIEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)±2%rdg±6dgt–– Status not stated Quote
KEW_3022 Kyoritsu Digital insulation resistance tester with auto-ranging 600 V 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction ManualIEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)±2%rdg±6dgt–– Status not stated Quote
KEW_3021 Kyoritsu Digital insulation tester 125 to 1000 V with continuity test 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction ManualIEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)±2%rdg±6dgt–– Status not stated Quote
KEW_3128 Kyoritsu 12 kV digital insulation resistance tester with internal memory 7170 (Power cord[EU]) or 7240 (Power cord[UK]); 7224A (Earth cord); 7225A (Guard cord); 7226A (Line probe); 7227A (Line probe with alligator clip); 8029 (Extension prod); 8212-USB (USB adapter); Instruction manualIEC 61010-1 CAT IV 600V Pollution degree 2, IEC 61010-2-034,; IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed.±2%rdg±3dgt–330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case Status not stated Quote
KEW_3126 Kyoritsu Insulation resistance tester 500 to 5000 V 7165A (Line probe), 7224A (Earth cord), 7225A (Guard cord) 8019 (Hook type prod), 9159 (Hard case) LR14 (Alkaline battery size C) × 8, Instruction manualIEC 61010-1 CAT III 600V Pollution degree 2 IEC 61010-031, IEC 61326±2%rdg±3dgt–205(L) × 152(W) × 94(D)mm Status not stated Quote
KEW_2413F Kyoritsu AC clamp meter 1000 A with 68 mm wide jaw 9094 (Carrying Case); 6F22 × 1 Instruction ManualIEC 61010-1 CAT III 300V; IEC 61010-2-032–φ 68mm max.250(L) × 130(W) × 50(D)mm Status not stated Quote
KEW_2413R Kyoritsu 1000 A AC clamp meter with 68 mm jaws 9094 (Carrying Case); 6F22 × 1 Instruction ManualIEC 61010-1 CAT III 300V Pollution degree 2; IEC 61010-2-032–φ 68mm max.– Status not stated Quote
KEW_3431 Kyoritsu 1000 V insulation resistance tester with backlit display –IEC 61010-1, 2-030 CAT Ⅲ 600V, IEC 61557-1, -2; IEC 61010-031, IEC 61010-2-034±5% of indicated value–– Status not stated Quote
KT_200 Kyoritsu Compact AC 400 A clamp meter with multimeter 7066A (Test leads); R03 (AAA) × 2, Instruction ManualIEC 61010-1 CAT Ⅲ 300V(ACA) / CAT ⅡI 600V Pollution degree 2; IEC 61010-2-032, IEC 61326-1–φ 30mm max.– Status not stated Quote
KT_203 Kyoritsu Compact AC/DC 400 A clamp meter with multimeter functions 7066A (Test leads); R03 (AAA) × 2, Instruction ManualIEC 61010-1 CAT Ⅲ 300V(ACA) / CAT Ⅱ 600V Pollution degree 2; IEC 61010-2-032, IEC 61326-1–φ 30mm max.– Status not stated Quote
KEW_1051 Kyoritsu True RMS handheld multimeter 6000 counts with K-type temperature 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; Blank coverIEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC)––– Status not stated Quote
KEW_1052 Kyoritsu True RMS handheld multimeter 6000 counts 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; Blank coverIEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC)––– Status not stated Quote
KEW_2046R Kyoritsu Multifunction AC/DC clamp meter with auto-ranging 7066A (Test leads); 9094 (Carrying case); Instruction Manual––Ø 33mm– Status not stated Quote
KEW_2062 Kyoritsu Tear-drop jaw three-phase power clamp meter 7290 (Voltage test lead set); 9198 (Carrying case); LR6(AA)×2, Instruction ManualIEC 61010-1, IEC 61010-2-032, IEC 61326-1,2-2 ClassB; CAT Ⅳ 300V / CAT Ⅲ 600V / CAT Ⅱ 1000V Pollution degree 2±0.7%rdg±3dgt (40.0 to 70.0Hz); ±0.3%rdg±5dgt (70.1Hz to 1KHz)φ 55 mm max. (busbar of 80mm × 30mm)– Status not stated Quote
KEW_5410 Kyoritsu Residual current device (RCD) tester with trip time measurement 7128A (Test leads); 7129A (Test lead with alligator clip); 8017 (Extension prod long) × 2; 9121 (Shoulder strap); 9147 (Cord case); Instruction manual, R6(AA) × 8IEC 61010-1 CAT Ⅲ 300V / CAT Ⅱ 400V Pollution degree2; IEC 61010-031, IEC 61557-1, 6 IEC 60529 (IP54)2%rdg±4dgt–167(L)×186(W)×89(D)mm Status not stated Quote
KEW_4106 Kyoritsu Earth resistance and resistivity tester 7229A (Earth precision measurement),; 7238A (Simplified measurement test leads),; 8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),; 8200-04 (Cord reel [4 pcs])×1 set,; 8212-USB (USB adapter),; 8923 (Fuse [0.5A/600V]) × 1 (included), 1 (spare),; 9121 (Shoulder strap),; 9125 (Carrying case),; R6 × 8, Instruction manualIEC 61010-1 CAT Ⅲ 300V / CAT Ⅳ150V Pollution degree 2; IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)––167(L) × 185(W) × 89(D) mm Status not stated Quote
KEW_2007R Kyoritsu True RMS 600/1000 A auto-ranging clamp meter 7066A (Test leads); 9079 (Carrying case); R03 (AAA) × 2, Instruction ManualIEC 61010-1 CAT IV 300V / CAT III 600V Pollution degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033,; IEC 61326-2-2(EMC), IEC 60529 IP40, EN 50581(RoHS)–φ 33mm max.– Status not stated Quote
KEW_3025B Kyoritsu High-voltage insulation resistance tester 2500 V 7165B (Line probe) *1; 7264A (Earth cord) *1; 7265A (Guard cord) *1; 8019 (Hook type prod); 9203 (Carrying case [Hard]); LR14 (Alkaline battery size C) × 8; Instruction manualIEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61326-1, 2-2±5%rdg±3dgt–177 (L) × 226 (W) × 100 (D) mm; 300 (L) × 315 (W) × 125 (D) mm (Carrying case [Hard]) Status not stated Quote
KEW_2200R Kyoritsu 1000 A AC clamp meter with ACV, DCV, Ω and continuity measurement 7107A (Test leads),; 9160 (Carrying case),; R03 (AAA) × 2, Instruction ManualIEC 61010-1 CAT IV 300V / CAT III 600V Pollution degree 2 (AC A),; CAT III 300V / CAT II 600V Pollution degree 2 (AC/DC V); IEC 61010-031, IEC 61010-2-032, IEC 61326 (EMC), EN 50581 (RoHS)–φ 33mm max.– Status not stated Quote
KEW_1019R Kyoritsu True RMS handheld multimeter with capacitance measurement 9188 (Hard case); CR2032 × 1; Instruction manualIEC 61010-1 CAT III 300V / CAT II 600V Pollution degree 2; IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2––– Status not stated Quote
KEW_2300R Kyoritsu AC/DC true RMS clamp meter with non-contact voltage 9113 (Carrying Case); R03 (1.5V) × 2; Instruction Manual––Max φ 10mm161(L) × 40(W) × 30(D)mm Status not stated Quote
KEW_1109S Kyoritsu Analog mirrored-scale handheld multimeter 7066A (Test leads); 8901 (Fuse[0.5A/250V]) × 1 (included), 1 (spare); R6 (AA) × 2; 6F22 × 1; Instruction Manual–––150(L) × 100(W) × 47(D)mm Status not stated Quote
KEW_6010B Kyoritsu Multi-function installation tester with earth and RCD testing 7122B (Test leads); KAMP10 (Test lead with IEC connector); 8923 (Fuse[0.5A/600V] × 1 (included), 1 (spare); 9092 (Cord case); 9121 (Shoulder strap); Shoulder pad; Instruction manual, R6(AA) × 8IEC 61010-1 CAT Ⅲ 300V Pollution Degree 2, IEC 61010-2-034, IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)±(3%rdg + 3dgt)–– Status not stated Quote
KEW_6315 Kyoritsu Three-phase power and power quality analyzer 7141B (Voltage test lead set); 7170 (Power cord[EU]) or 7240 (Power cord[UK]); 7219 (USB cable); 8326-02 (SD card [2GB]); 9125 (Carrying case); Input terminal plate × 6, Quick manual, LR6× 6IEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V / CAT Ⅱ 1000V Pollution degree 2, IEC 61010-2-030, IEC 61010-031,; IEC 61326, EN 50160 IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7600.0V Range : (sine wave 40 to 70Hz); 10% to 150% against 100V or more of nominal V : Nominal V±0.5%; Out of above range : ±0.2%rdg±0.2%f.s.; 1000V Range : ±0.2%rdg±0.2%f.s.(sine wave 40 to 70Hz)–– Status not stated Quote
KEW_4105A Kyoritsu 2- and 3-pole earth tester with earth voltage measurement 7095A (Earth resistance test leads (Red 20m, Yellow 10m, Green 5m/1set)); 7127B (Simplified measurement probe); 8032 (Auxiliary earth spikes[2 spikes/1set]); 9121 (shoulder strap); 9084 (Carrying case); R6(AA) × 6, Instruction manualIEC 61010-1 CAT Ⅲ300 V Pollution degree 2; IEC 61010-2-030, IEC 61557-1,5, IEC 60529 (IP54)±1%rdg±4dgt–105(L) × 158(W) × 70(D) mm (including case lid) Status not stated Quote

Manufacturers similar to Kyoritsu

Makers with the most products in the same categories.

Documents

440 documents · 440 manual · Browse all in the document center

8 of 440 documents shown. See all

Frequently asked questions about Kyoritsu

Which Kyoritsu products does Atlas Electronics list?

Products in 10 categories, mainly Clamp Meters, Insulation Resistance Testers, Installation and Earth Testers.

How do I get a price for a Kyoritsu product?

Prices and lead times are given on quotation: use "Request a quote" on a product page, or add several references to your quote request.

Where can I find Kyoritsu datasheets?

440 manufacturer documents are linked: in the Documents tab of each product and in the document center.

Where is Kyoritsu based?

Kyoritsu is based in Japan.