The first part of the Kyoritsu selection covers clamp meters; it also includes insulation resistance testers and installation and earth testers.
Kyoritsu offers a handheld digital multimeter with bar graph (KEW_1011) alongside a true-RMS digital multimeter with a current clamp (KEW_1021R).
- KEW_1011 — Handheld digital multimeter with bar graph.
- KEW_1021R — True-RMS digital multimeter with a current clamp.
- KEW_1062 — Handheld industrial TRMS multimeter with 50,000 counts.
Product families
- Clamp Meters 51 products
- Insulation Resistance Testers 42 products
- Installation and Earth Testers 31 products
- Handheld Multimeters 25 products
- Submeters 14 products
- Current Probes 9 products
- Test Leads and Probes 7 products
- Current Transformers Sensors 4 products
- Infrared Thermometers 3 products
- Rogowski Coils 1 product
Technologies
Matched from product names, summaries and categories.
Products
| Quote basket | Action | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| KEW_8177 | Kyoritsu | AC clamp current sensor 10 A, 500 mV output | 9095 (Carrying case); Instruction manual | IEC 61010-1, IEC 61010-2-032 CAT Ⅲ 300V Pollution degree 2, IEC 61326-1 | ±1.0%rdg±0.025mV (40 to 70Hz); ±4.0%rdg±0.025mV (30Hz to 5kHz, with inputs of 100mA or more) | Ø 40mm | 128(L) × 81(W) × 36(D)mm | Status not stated | Quote | |
| KEW_8161 | Kyoritsu | AC clamp sensor for digital multimeter | Instruction manual | IEC 61010-1 CAT III 300V pollution degree 2, IEC 61010-2-032 | ±2.0%rdg±3.0mV (45 to 65Hz) ±2.5%rdg±3.0mV (65Hz to 1kHz) | Ø 24 | 97(L) × 59(W) × 26(D) mm | Status not stated | Quote | |
| KEW_8178 | Kyoritsu | AC clamp meter with 500 mV output for KEW 5050 leakage | 9094 (Carrying case), Instruction manual | IEC 61010-1, IEC 61010-2-032 CAT Ⅲ 300V Pollution degree 2, IEC 61326-1 | ±1.0%rdg±0.025mV (40 to 70Hz); ±4.0%rdg±0.025mV (30Hz to 5kHz, with inputs of 100mA or more) | Ø 68mm | 186(L) × 129(W) × 53(D)mm | Status not stated | Quote | |
| KEW_8129 | Kyoritsu | Flexible air-core AC current probe up to 3000 A | 8129-01 (for 1ch) Instruction Manual, 7199 (Output Cable) x1, 9137 (Carrying Case) 8129-02 (for 2ch) Instruction Manual, 7199 (Output Cable) x2, 9137 (Carrying Case) 8129-03 (for 3ch)Instruction Manual, 7199 (Output Cable) x3, 9137 (Carrying Case) | IEC 61010-1, IEC 61010-2-032 CAT III 600V Pollution degree2, IEC 61326 | ±1.0%rdg (45 - 65Hz) | max.Ø 150mm | 111(L) x 61(W) x 43(D) mm (except for protrusions) | Status not stated | Quote | |
| KEW_8130 | Kyoritsu | AC clamp meter with air core coil, 1000 A | 9095 (Carrying case); Instruction manual, Cable marker | IEC 61010-1, IEC 61010-2-030; IEC 61010-2-032 CAT IV 300V / CAT III 600V Pollution degree 2; IEC 61326 | ±0.8%rdg±0.2mV (45Hz to 65Hz); ±1.5%rdg±0.4mV (40Hz to 1kHz) | max.Ø 110mm | – | Status not stated | Quote | |
| KEW_8135 | Kyoritsu | Flexible Rogowski coil current sensor 50 A AC | 9095 (Carrying case); Instruction manual, Cable marker | IEC 61010-1, IEC 61010-2-032 CAT IV 300V / CAT III 600V Pollution degree 2, IEC 61326 | ±1.0%rdg±0.5mV (45 to 65Hz) (0 to 50A); ±1.5%rdg±0.5mV (40 to 300Hz) (0 to 20A); ±1.5%rdg±0.5mV (300Hz to 1kHz) (0 to 5A) | φ 75 mm (max) | 65(L)×24(W)×22(D)mm | Status not stated | Quote | |
| KEW_8121 | Kyoritsu | AC 100 A clamp meter with voltage output | 9095 (Carrying case); Instruction manual, Cable marker | IEC 61010-1, IEC 61010-2-032 CAT III 300V pollution degree 2, IEC 61326 | ±2.0%rdg±0.3mV (50/60Hz); ±3.0%rdg±0.5mV (40Hz to 1kHz) | Ø 24mm | 97(L) x 59(W) x 26(D) mm | Status not stated | Quote | |
| KEW_8115 | Kyoritsu | AC/DC current clamp sensor for digital multimeters | 9095 (Carrying case); LR03×2, Instruction manual | IEC 61010-1 CAT III 300V Pollution degree 2, IEC 61010-2-032, IEC 61326-1 | – | Max. Ø 12mm | 127(L)×42(W)×22(D) mm | Status not stated | Quote | |
| KEW_2210R | Kyoritsu | Flexible clamp meter with TRMS measurement | 9174 (Carrying case); LR03(AAA)×2, Insruction manual | IEC 61010-1, IEC 61010-2-032; CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree 2; IEC 61326-1(EMC), IEC 60529 IP40, EN50581(RoHS) | ±3%rdg±5dgt [45 to 500Hz]; (At the center of the circle formed by the flexible sensor) | φ 150mm max. | 120(L)×70(W)×26(D):Display unit; φ 8.5mm approx.:Cable diameter; 1.8m : Cable length | Status not stated | Quote | |
| KEW_2117R | Kyoritsu | True RMS 1000 A clamp meter with fully safety jaws | 7066A (Test leads); 9079 (Carrying case); R03 (AAA) × 2, Instruction Manual | IEC 61010-1 CAT IV 300V / CAT III 600V Pollution degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033,; IEC 61326-2-2(EMC), IEC 60529 IP 40, EN50581(RoHS) | – | φ 33mm max. | – | Status not stated | Quote | |
| KEW_2204R | Kyoritsu | Flexible AC Clamp Meter with True RMS | 9174 (Carrying case); LR03(AAA)×2, Insruction manual | IEC 61010-1, IEC 61010-2-032; CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree 2; IEC 61326-1(EMC), IEC 60529 IP40, EN50581(RoHS) | ±3%rdg±5dgt [45 to 500Hz]; (At the center of the circle formed by the flexible sensor) | φ 70mm max. | 120(L)×70(W)×26(D):Display unit; φ 5.5mm approx.:Cable diameter; 1.8m : Cable length | Status not stated | Quote | |
| KEW_2127R | Kyoritsu | Fully insulated TRMS clamp meter | 7066A (Test leads); 9079 (Carrying case); R03(AAA)×2 Instruction manual | IEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033,; IEC 61326-2-2(EMC), IEC 60529 IP40, EN 50581(RoHS) | – | φ 33mm max. | – | Status not stated | Quote | |
| KEW_3025A | Kyoritsu | High Voltage Insulation Resistance Tester 2500 V | 7165A (Line probe); 7264 (Earth cord); 7265 (Guard cord); 8019 (Hook type prod); 9180 (Carrying case [Hard]); LR14 (Alkaline battery size C) × 8; Instruction manual | IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61326-1, 2-2 | ±5%rdg±3dgt | – | 177 (L) × 226 (W) × 100 (D) mm; 300 (L) × 315 (W) × 125 (D) mm (Carrying case [Hard]) | Status not stated | Quote | |
| KEW_6016 | Kyoritsu | Multifunction installation tester with loop and RCD testing | 7188A (Distribution board fuse test lead set) 7281 (Test leads with remote control switch) 7218A (Power cord [EU]) (*6) 7228A (Earth resistance test leads) 8032 (Auxiliary earth spikes) 8212-USB (USB adaptor with KEW Report (Software)) 9084 (Cord case) 9142 (Carrying case) 9121 (Shoulder strap) Cord case, Buckle, Battery, Instruction manual | IEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031, IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC) | – | – | 136(L) X 235(W) X 114(D)mm | Status not stated | Quote | |
| KEW_2009R | Kyoritsu | TRMS AC/DC clamp meter up to 2000 A | 7107A (Test leads); 9094 (Carrying case); R6 (AA) × 2,; Instruction Manual | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61326-2-2 | – | φ 55mm max. | – | Status not stated | Quote | |
| KEW_3023A | Kyoritsu | 1000 V digital insulation resistance tester with continuity test | 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual | IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40) | ±2%rdg±6dgt | – | – | Status not stated | Quote | |
| KEW_2003A | Kyoritsu | AC/DC clamp meter up to 2000 A | 7107A (Test leads); 9094 (Carrying Case); R6 (AA) × 2, Instruction Manual | – | – | Ø 55mm max. | – | Status not stated | Quote | |
| KEW_6310 | Kyoritsu | Three-phase power quality analyzer | 7141B (Voltage test lead set) 7148 (USB cable) 7170 (Power cord) 9125 (Carrying case) 8307 (Compact flash card 128MB) 8319 (CF Card reader) Input terminal plate (6-kind) Alkaline size AA battery (LR6) × 6 PQA MASTER (PC Software) Quick manual Cable marker × 32 | IEC 61010-1 CAT III 600V Pollution degree 2 IEC 61010-031, IEC 61326 | ±0.3%rdg±0.2%f.s. (sine wave, 45 - 65Hz) | – | 175(L)×120(W)×68(D) mm | Status not stated | Quote | |
| KEW_2056R | Kyoritsu | AC/DC clamp meter with voltage and capacitance measurement | 7066A (Test leads); 9094 (Carrying case) Instruction Manual | – | – | Ø 40mm | – | Status not stated | Quote | |
| KEW_3125A | Kyoritsu | High voltage insulation tester 250 V to 5000 V | 7165A (Line probe); 7264 (Earth cord); 7265 (Guard cord); 8019 (Hook type prod); 9181 (Carrying case [Hard]); LR14 (Alkaline battery size C) × 8; Instruction manual | IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61326-1, 2-2 | ±2%rdg±3dgt | – | 177 (L) × 226 (W) × 100 (D) mm; 300 (L) × 315 (W) × 125 (D) mm (Carrying case [Hard]) | Status not stated | Quote | |
| KEW_3022A | Kyoritsu | Digital insulation resistance tester with 4 test voltages | 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual | IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40) | 5MΩ (50/100/250V) 50MΩ (500V) | – | – | Status not stated | Quote | |
| KEW_3121A | Kyoritsu | 2500 V DC Insulation Tester with Auto-Ranging | 7165A (Line probe) (3m) 7224A (Earth cord) (1.5m) 7225A (Guard code) (1.5m) 9158 (Hard case) R6 (AA) × 8 Instruction manual | – | ± 5% rdg | – | 200 (L) × 140 (W) × 80 (D) mm | Status not stated | Quote | |
| KEW_3122A | Kyoritsu | High voltage insulation tester, 5000 V DC | 7165A (Line probe) (3m) 7224A (Earth cord) (1.5m) 7225A (Guard code) (1.5m) 9158 (Hard case) R6 (AA) × 8 Instruction manual | – | ± 5% rdg | – | 200 (L) × 140 (W) × 80 (D) mm | Status not stated | Quote | |
| KEW_3021A | Kyoritsu | Digital insulation tester 125 to 1000 V with continuity test | 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual | IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40) | ±2%rdg±6dgt | – | – | Status not stated | Quote | |
| KEW_2200 | Kyoritsu | 1000 A AC clamp meter with DMM functions and continuity buzzer | 7107A (Test leads),; 9160 (Carrying case),; R03 (AAA) × 2, Instruction Manual | IEC 61010-1 CAT III 600V Pollution degree 2 (AC A),; CAT III 300V / CAT II 600V Pollution degree 2 (AC/DC V); IEC 61010-031, IEC 61010-2-032, IEC 61326 (EMC) | – | φ 33mm max. | – | Status not stated | Quote | |
| KEW_3023 | Kyoritsu | Digital insulation tester with 4 test voltages | 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual | IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40) | ±2%rdg±6dgt | – | – | Status not stated | Quote | |
| KEW_3022 | Kyoritsu | Digital insulation resistance tester with auto-ranging 600 V | 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual | IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40) | ±2%rdg±6dgt | – | – | Status not stated | Quote | |
| KEW_3021 | Kyoritsu | Digital insulation tester 125 to 1000 V with continuity test | 7150A (Remote control switch set), 9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual | IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40) | ±2%rdg±6dgt | – | – | Status not stated | Quote | |
| KEW_3128 | Kyoritsu | 12 kV digital insulation resistance tester with internal memory | 7170 (Power cord[EU]) or 7240 (Power cord[UK]); 7224A (Earth cord); 7225A (Guard cord); 7226A (Line probe); 7227A (Line probe with alligator clip); 8029 (Extension prod); 8212-USB (USB adapter); Instruction manual | IEC 61010-1 CAT IV 600V Pollution degree 2, IEC 61010-2-034,; IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed. | ±2%rdg±3dgt | – | 330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case | Status not stated | Quote | |
| KEW_3126 | Kyoritsu | Insulation resistance tester 500 to 5000 V | 7165A (Line probe), 7224A (Earth cord), 7225A (Guard cord) 8019 (Hook type prod), 9159 (Hard case) LR14 (Alkaline battery size C) × 8, Instruction manual | IEC 61010-1 CAT III 600V Pollution degree 2 IEC 61010-031, IEC 61326 | ±2%rdg±3dgt | – | 205(L) × 152(W) × 94(D)mm | Status not stated | Quote | |
| KEW_2413F | Kyoritsu | AC clamp meter 1000 A with 68 mm wide jaw | 9094 (Carrying Case); 6F22 × 1 Instruction Manual | IEC 61010-1 CAT III 300V; IEC 61010-2-032 | – | φ 68mm max. | 250(L) × 130(W) × 50(D)mm | Status not stated | Quote | |
| KEW_2413R | Kyoritsu | 1000 A AC clamp meter with 68 mm jaws | 9094 (Carrying Case); 6F22 × 1 Instruction Manual | IEC 61010-1 CAT III 300V Pollution degree 2; IEC 61010-2-032 | – | φ 68mm max. | – | Status not stated | Quote | |
| KEW_3431 | Kyoritsu | 1000 V insulation resistance tester with backlit display | – | IEC 61010-1, 2-030 CAT Ⅲ 600V, IEC 61557-1, -2; IEC 61010-031, IEC 61010-2-034 | ±5% of indicated value | – | – | Status not stated | Quote | |
| KT_200 | Kyoritsu | Compact AC 400 A clamp meter with multimeter | 7066A (Test leads); R03 (AAA) × 2, Instruction Manual | IEC 61010-1 CAT Ⅲ 300V(ACA) / CAT ⅡI 600V Pollution degree 2; IEC 61010-2-032, IEC 61326-1 | – | φ 30mm max. | – | Status not stated | Quote | |
| KT_203 | Kyoritsu | Compact AC/DC 400 A clamp meter with multimeter functions | 7066A (Test leads); R03 (AAA) × 2, Instruction Manual | IEC 61010-1 CAT Ⅲ 300V(ACA) / CAT Ⅱ 600V Pollution degree 2; IEC 61010-2-032, IEC 61326-1 | – | φ 30mm max. | – | Status not stated | Quote | |
| KEW_1051 | Kyoritsu | True RMS handheld multimeter 6000 counts with K-type temperature | 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; Blank cover | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC) | – | – | – | Status not stated | Quote | |
| KEW_1052 | Kyoritsu | True RMS handheld multimeter 6000 counts | 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; Blank cover | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC) | – | – | – | Status not stated | Quote | |
| KEW_2046R | Kyoritsu | Multifunction AC/DC clamp meter with auto-ranging | 7066A (Test leads); 9094 (Carrying case); Instruction Manual | – | – | Ø 33mm | – | Status not stated | Quote | |
| KEW_2062 | Kyoritsu | Tear-drop jaw three-phase power clamp meter | 7290 (Voltage test lead set); 9198 (Carrying case); LR6(AA)×2, Instruction Manual | IEC 61010-1, IEC 61010-2-032, IEC 61326-1,2-2 ClassB; CAT Ⅳ 300V / CAT Ⅲ 600V / CAT Ⅱ 1000V Pollution degree 2 | ±0.7%rdg±3dgt (40.0 to 70.0Hz); ±0.3%rdg±5dgt (70.1Hz to 1KHz) | φ 55 mm max. (busbar of 80mm × 30mm) | – | Status not stated | Quote | |
| KEW_5410 | Kyoritsu | Residual current device (RCD) tester with trip time measurement | 7128A (Test leads); 7129A (Test lead with alligator clip); 8017 (Extension prod long) × 2; 9121 (Shoulder strap); 9147 (Cord case); Instruction manual, R6(AA) × 8 | IEC 61010-1 CAT Ⅲ 300V / CAT Ⅱ 400V Pollution degree2; IEC 61010-031, IEC 61557-1, 6 IEC 60529 (IP54) | 2%rdg±4dgt | – | 167(L)×186(W)×89(D)mm | Status not stated | Quote | |
| KEW_4106 | Kyoritsu | Earth resistance and resistivity tester | 7229A (Earth precision measurement),; 7238A (Simplified measurement test leads),; 8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),; 8200-04 (Cord reel [4 pcs])×1 set,; 8212-USB (USB adapter),; 8923 (Fuse [0.5A/600V]) × 1 (included), 1 (spare),; 9121 (Shoulder strap),; 9125 (Carrying case),; R6 × 8, Instruction manual | IEC 61010-1 CAT Ⅲ 300V / CAT Ⅳ150V Pollution degree 2; IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54) | – | – | 167(L) × 185(W) × 89(D) mm | Status not stated | Quote | |
| KEW_2007R | Kyoritsu | True RMS 600/1000 A auto-ranging clamp meter | 7066A (Test leads); 9079 (Carrying case); R03 (AAA) × 2, Instruction Manual | IEC 61010-1 CAT IV 300V / CAT III 600V Pollution degree 2; IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033,; IEC 61326-2-2(EMC), IEC 60529 IP40, EN 50581(RoHS) | – | φ 33mm max. | – | Status not stated | Quote | |
| KEW_3025B | Kyoritsu | High-voltage insulation resistance tester 2500 V | 7165B (Line probe) *1; 7264A (Earth cord) *1; 7265A (Guard cord) *1; 8019 (Hook type prod); 9203 (Carrying case [Hard]); LR14 (Alkaline battery size C) × 8; Instruction manual | IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2; IEC 61010-031, IEC 61326-1, 2-2 | ±5%rdg±3dgt | – | 177 (L) × 226 (W) × 100 (D) mm; 300 (L) × 315 (W) × 125 (D) mm (Carrying case [Hard]) | Status not stated | Quote | |
| KEW_2200R | Kyoritsu | 1000 A AC clamp meter with ACV, DCV, Ω and continuity measurement | 7107A (Test leads),; 9160 (Carrying case),; R03 (AAA) × 2, Instruction Manual | IEC 61010-1 CAT IV 300V / CAT III 600V Pollution degree 2 (AC A),; CAT III 300V / CAT II 600V Pollution degree 2 (AC/DC V); IEC 61010-031, IEC 61010-2-032, IEC 61326 (EMC), EN 50581 (RoHS) | – | φ 33mm max. | – | Status not stated | Quote | |
| KEW_1019R | Kyoritsu | True RMS handheld multimeter with capacitance measurement | 9188 (Hard case); CR2032 × 1; Instruction manual | IEC 61010-1 CAT III 300V / CAT II 600V Pollution degree 2; IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 | – | – | – | Status not stated | Quote | |
| KEW_2300R | Kyoritsu | AC/DC true RMS clamp meter with non-contact voltage | 9113 (Carrying Case); R03 (1.5V) × 2; Instruction Manual | – | – | Max φ 10mm | 161(L) × 40(W) × 30(D)mm | Status not stated | Quote | |
| KEW_1109S | Kyoritsu | Analog mirrored-scale handheld multimeter | 7066A (Test leads); 8901 (Fuse[0.5A/250V]) × 1 (included), 1 (spare); R6 (AA) × 2; 6F22 × 1; Instruction Manual | – | – | – | 150(L) × 100(W) × 47(D)mm | Status not stated | Quote | |
| KEW_6010B | Kyoritsu | Multi-function installation tester with earth and RCD testing | 7122B (Test leads); KAMP10 (Test lead with IEC connector); 8923 (Fuse[0.5A/600V] × 1 (included), 1 (spare); 9092 (Cord case); 9121 (Shoulder strap); Shoulder pad; Instruction manual, R6(AA) × 8 | IEC 61010-1 CAT Ⅲ 300V Pollution Degree 2, IEC 61010-2-034, IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40) | ±(3%rdg + 3dgt) | – | – | Status not stated | Quote | |
| KEW_6315 | Kyoritsu | Three-phase power and power quality analyzer | 7141B (Voltage test lead set); 7170 (Power cord[EU]) or 7240 (Power cord[UK]); 7219 (USB cable); 8326-02 (SD card [2GB]); 9125 (Carrying case); Input terminal plate × 6, Quick manual, LR6× 6 | IEC 61010-1 CAT Ⅳ 300V / CAT Ⅲ 600V / CAT Ⅱ 1000V Pollution degree 2, IEC 61010-2-030, IEC 61010-031,; IEC 61326, EN 50160 IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7 | 600.0V Range : (sine wave 40 to 70Hz); 10% to 150% against 100V or more of nominal V : Nominal V±0.5%; Out of above range : ±0.2%rdg±0.2%f.s.; 1000V Range : ±0.2%rdg±0.2%f.s.(sine wave 40 to 70Hz) | – | – | Status not stated | Quote | |
| KEW_4105A | Kyoritsu | 2- and 3-pole earth tester with earth voltage measurement | 7095A (Earth resistance test leads (Red 20m, Yellow 10m, Green 5m/1set)); 7127B (Simplified measurement probe); 8032 (Auxiliary earth spikes[2 spikes/1set]); 9121 (shoulder strap); 9084 (Carrying case); R6(AA) × 6, Instruction manual | IEC 61010-1 CAT Ⅲ300 V Pollution degree 2; IEC 61010-2-030, IEC 61557-1,5, IEC 60529 (IP54) | ±1%rdg±4dgt | – | 105(L) × 158(W) × 70(D) mm (including case lid) | Status not stated | Quote |
Manufacturers similar to Kyoritsu
Makers with the most products in the same categories.
Documents
440 documents · 440 manual · Browse all in the document center
- KEW 2056R — KEW 2056R Product Catalog (English) KEW_2056R
- KEW 3431 — KEW 3431 Instruction Manual (French) KEW_3431
- KEW 2009R — KEW 2009R Instruction Manual (English) KEW_2009R
- MODEL 8112BNC — MODEL 8112BNC Instruction Manual (English) 8112BNC
- KEW 6310 — KEW 6310 Quick Manual (Spanish) KEW_6310
- KEW 1051 — KEW 1051 Instruction Manual (English) KEW_1051
- KEW 1052 — KEW 1052 Instruction Manual (French) KEW_1052
- MODEL 3161A — MODEL 3161A Instruction Manual (English) MODEL_3161A
8 of 440 documents shown. See all
Frequently asked questions about Kyoritsu
Which Kyoritsu products does Atlas Electronics list?
Products in 10 categories, mainly Clamp Meters, Insulation Resistance Testers, Installation and Earth Testers.
How do I get a price for a Kyoritsu product?
Prices and lead times are given on quotation: use "Request a quote" on a product page, or add several references to your quote request.
Where can I find Kyoritsu datasheets?
440 manufacturer documents are linked: in the Documents tab of each product and in the document center.
Where is Kyoritsu based?
Kyoritsu is based in Japan.